■ Award- May 2020 Architectural Institute of Japan, AIJ Prize Research Paper Division, Study on prediction of heat and moisture transfer in human-clothing system and thermal and dryness sensations in non-steady state
- Oct. 2016 人間-生活環境系学会, 人間-生活環境系学会論文賞, 個人Japan society
- Sep. 2005 日本建築学会, 日本建築学会奨励賞, 論文
- Dec. 2001 人間-生活環境系学会, 人間-生活環境系会議奨励賞, 論文
- Corresponding, Elsevier BV, Jul. 2024, Journal of Building Engineering, 89, 109300 - 109300, English[Refereed]Scientific journal
- Last, Elsevier BV, Jun. 2024, Cold Regions Science and Technology, 222, 104199 - 104199, English[Refereed]Scientific journal
- When the water content of a porous material is high, air entrapped in the pore space is expected to affect water transfer through the pores. To understand the effects of air entrapment on water transfer in porous building materials in the high-water-saturation region, we examined the water transfer characteristics corresponding to significantly small air entrapment effects. First, we conducted two sets of water uptake experiments. In the first experiment, using three building materials, the time evolution of the amount of water absorption was measured at a low air pressure near vacuum (several kPa). In the second experiment, the water content profile during water uptake was measured using the gamma-ray attenuation method. The experimental results showed that low air pressure accelerated the water uptake by the brick and aerated concrete specimens, whereas water uptake by the calcium silicate board specimens was not significantly affected. These differences among materials were analyzed from a pore structure viewpoint. Moreover, gamma-ray attenuation measurements confirmed that the obtained water content profile was qualitatively similar at atmospheric and low air pressures, although the low air pressure increased both the water content of the material after capillary absorption and the wetting front propagation rate. Finally, simultaneous water and air transfer calculations based on the air and liquid water balance in a material reproduced the measured water absorption rates well, confirming that air entrapment and pressure development in the pores can significantly reduce the rate of water uptake and water content after capillary absorption. The calculation results also indicated that the air pressure in a material did not significantly increase at early water uptake stages where local water content was not high, which supported the general assumption that treating the liquid-water transfer in porous building materials as a one-component flow is valid in most cases.Last, SAGE Publications, Mar. 2024, Journal of Building Physics, English[Refereed]Scientific journal
- Abstract When a porous material is near capillary saturation, entrapped air is expected to affect water transfer through the pores. Based on the results of water absorption tests at reduced air pressure, Janssen et al. (Energy Procedia, 2015) demonstrated that air entrapment prevents water absorption above capillary saturation. In this study, to understand the air entrapment effects on water transfer in the high-water-saturation region, we further examined the water transfer characteristics corresponding to extremely small air entrapment effects. First, using three common porous building materials, water uptake experiments were conducted at low air pressure near vacuum (several kilopascals), and the time evolution of the water absorption was measured. The results show that low air pressure accelerates water uptake by brick and aerated concrete specimens, whereas the water uptake by calcium silicate board specimens is not significantly affected. These differences among the materials are discussed from the viewpoint of the pore structure. Furthermore, the results of simultaneous water and air transfer calculations confirm that air entrapment and pressure development in the pores can significantly reduce the rate of water uptake and the water content that a material can reach after capillary absorption.Last, IOP Publishing, Dec. 2023, Journal of Physics: Conference Series, 2654(1) (1), 012033 - 012033, English[Refereed]International conference proceedings
- Last, Nov. 2023, J. Human and Living Environment, 30(2) (2), 75 - 81, Japanese[Refereed]Scientific journal
- Corresponding, Sep. 2023, Proceedings of SWBSS ASIA 2023 (First International Conference in Asia on Salt Weathering of Buildings and Stone Sculptures), Nara, Japan, 65 - 73, EnglishMeasurement of salinity in indoor air and estimation of salt sources in aquariums in coastal areas[Refereed]International conference proceedings
- Corresponding, Elsevier BV, Aug. 2023, Journal of Building Engineering, 73, 106803 - 106803, English[Refereed]Scientific journal
- Last, Elsevier BV, Jul. 2023, Journal of Building Engineering, 71, 106578 - 106578, English[Refereed]Scientific journal
- Eye discomfort is a major complaint reported in indoor spaces and has been suggested to be exacerbated by environmental conditions such as low humidity and high air velocity. Wearing face masks, which has become essential in our daily lives during the COVID-19 pandemic, can also cause eye discomfort by affecting the microclimate around the eyes. We conducted a pilot study to evaluate the effect of wearing masks on eye discomfort by measuring the physical environment around the eyes and short-term physiological and psychological responses and comparing them with and without surgical face masks. The results showed that when the participant wore a mask, exhaled air flowed out through the gap at the top edge of the mask, resulting in a higher air velocity and absolute humidity around the eyes than when the mask was not worn. No significant differences were found in subjective discomfort, tear-film stability, ocular surface temperature or blink frequency. However, the tear evaporation rate, estimated based on physical measurements, was greater when wearing a mask than when not wearing it. This study revealed that wearing face masks can negatively affect the environment around the eyes in terms of tear-film health.Last, SAGE Publications, May 2023, Indoor and Built Environment, 32(9) (9), 1828 - 1842, English[Refereed]Scientific journal
- The sorption property of porous building materials in the hygroscopic region (sorption isotherm) is an important input to hygrothermal simulation. In this study, we proposed efficient and accurate protocols to obtain sorption isotherms using the static desiccator method. We developed a calculation model for three-dimensional simultaneous heat and moisture transfer in a material corresponding to the measurement specified in ISO 12571. Using an international database of the material properties, we conducted numerical simulations of the sorption process for five types of materials. The evolution of the amount of adsorbed moisture in a specimen and the time to reach equilibrium during the measurement were calculated under various humidity levels and specimen dimensions. According to the simulated results, we improved timing and interval for weighting the specimen to confirm the attainment of equilibrium for each type of a material and for each humidity level from the viewpoint of efficiency and accuracy. Meanwhile, the influence of size of a specimen on the time necessary to obtain the results was quantitatively demonstrated. Moreover, it was demonstrated that the method used for the determination of the attainment of equilibrium provided in ISO 12571 can underestimate the moisture content of materials with low moisture content and vapor permeability, and a policy to reduce risks of the underestimation was proposed.Last, SAGE Publications, Jan. 2023, Journal of Building Physics, 46(5) (5), 541 - 566, English[Refereed]Scientific journal
- In order to prevent heat stroke during bathing, it is effective to use a thermal model of the human body that can appropriately predict the increase in core temperature during bathing under various temperature conditions. In this study, we developed an improved version of the existing Two-node model by dividing the core layer into two parts, and showed the validity of the improved model by comparing the results of the calculation by the model with those of a 10-minute bathing experiment for six male and six female subjects under six conditions: two levels of water temperature (40°C and 42°C) and three seasons (summer 30°C, fall 24°C, and winter 18°C). The error between the measured rectal temperature and the calculated core temperature was 0.15°C in the conventional Two-node model, but improved to 0.11°C in the proposed version of the model. When limited to the 40°C water temperature condition in winter, the error was greatly improved from 0.21°C to 0.10°C. These results indicate that the proposed version of the model, which divides the core layer of Two-node model into two parts, can appropriately predict the rise in core temperature during bathing.Lead, Japanese Society of Biometeorology, Nov. 2022, JAPANESE JOURNAL OF BIOMETEOROLOGY, 59(3-4) (3-4), 79 - 88, Japanese[Refereed]Scientific journal
- Nov. 2022, J. Human and Living Environment, 29(2) (2), 45 - 52, JapaneseFundamental research for indoor humidity control using skin appearance as evaluation index[Refereed]Scientific journal
- Eye discomfort due to dryness is one of the major complaints reported in indoor spaces. The purpose of this study was to quantitatively evaluate the effect of low humidity on eye discomfort in soft contact lens (SCL) and non-CL wearers. In addition to subjective sensations, physiological parameters related to eye discomfort including tear-film parameters and blink patterns were comparatively evaluated between relative humidities of 10% and 45% at 23°C. For both the SCL and non-CL wearer groups, low humidity had a significant effect on some of the measured physiological parameters. The SCL group showed lower ocular surface temperature and larger temperature differential after blinking at 10% relative humidity (RH) than that at 45% RH, indicating faster tear evaporation. Furthermore, their tear films tended to be thinner and have a shorter break-up time at 10% RH than at 45% RH. The non-CL group showed a significantly higher blink frequency and longer eye-closure time at 10% RH than at 45% RH, presumably as a compensatory response to the disturbance of the tear film due to low humidity. These results suggest the importance of humidity control in indoor spaces in terms of tear-film quality, which contributes to eye discomfort.Last, SAGE Publications, Sep. 2022, Indoor and Built Environment, 32(3) (3), 590 - 602, English[Refereed]Scientific journal
- Last, Feb. 2022, J. Environ. Eng., AIJ, 87(792) (792), 84 - 93, JapaneseINFLUENCE OF HIGH HUMIDITY ON DISCOMFORT SENSATION UNDER CONDITIONS SLIGHTLY INCLINED TO HOT SIDE FROM THERMAL NEUTRALITY[Refereed]Scientific journal
- Depending on the data source used, the material hygrothermal properties that are used in the numerical analysis of simultaneous heat and moisture transfer will not be consistent. Differences in measurement methods and the individuality of specimens account for this. It is necessary to choose values from these different physical property sets to conduct a numerical calculation, which can cause the calculated results to differ. The subsequent range of variation in the calculated results should be quantitatively evaluated. In this study, the physical properties of several types of porous building materials were first gathered from four databases. The data were then categorized based on the kind of material and compared in terms of each physical property (density, porosity, specific heat, moisture capacity, thermal conductivity, and vapor permeability). The density, porosity, and specific heat varied by 10% on average, and the moisture capacity, thermal conductivity, and vapor permeability varied by 20% or more for all types of materials. In particular, the vapor permeability of plywood and moisture capacity of gypsum board differed by 50%. The influence that these physical property value variations had on hygrothermal calculation results was then quantitatively demonstrated for moisture and heat flow rate under a step change in the relative humidity or temperature of indoor air for a single layer wall. The moisture and heat flow rate into a single layer wall fluctuated by approximately 10%–40% due to differences in the vapor permeability and moisture capacity of the materials. For all types of materials, moisture was transferred more slowly than heat. Therefore, differences in moisture property values, such as vapor permeability and moisture capacity, influenced the results more significantly. Moreover, the moisture flow was accompanied by a phase change. The differences in moisture property values thus affected the heat flow.Last, SAGE Publications, Oct. 2021, Journal of Building Physics, 45(6) (6), 757 - 773, English[Refereed]Scientific journal
- Lead, Wiley, Jan. 2021, Indoor Air, 31(1) (1), 250 - 263, English[Refereed]Scientific journal
- Lead, Aug. 2020, Journal of the Human-Environment System, 23(1) (1), 31 - 43, EnglishInfluence of temperature and humidity of ambient air on sensation of dryness during respiration[Refereed]Scientific journal
- Elsevier BV, Aug. 2020, Building and Environment, 183, 107123 - 107123[Refereed]Scientific journal
- Lead, Apr. 2020, 日本建築学会環境系論文集, 85(770) (770), 249 - 258, JapaneseImprovement of indoor environment based on multiple interzonal airflow analysis, Study on indoor environment of welfare facility for the elderly in winter[Refereed]Scientific journal
- Lead, Nov. 2018, Journal of Human and Living Environment, 25(2) (2), 85 - 91, JapaneseMeasurement of Change in Eye Surface Temperature in Response to Blinking[Refereed]Scientific journal
- Sep. 2018, Proceedings of 7th International Building Physics Conference, IBPC2018, (177) (177), 1 - 6, EnglishEvaluating the energy consumption and heat loss in the hot water supply and heating systems of a nursing home[Refereed]International conference proceedings
- Architectural Institute of Japan, Apr. 2017, Journal of Environmental Engineering (Japan), 82(734) (734), 337 - 345, English[Refereed]Scientific journal
- Nov. 2016, Proceedings of the 5th International Conference on Human-Environment System, 20154, 1 - 9, EnglishMeasurement of ocular surface temperature for determination of moisture evaporation rate at eyes and prevention of sensation of dryness[Refereed]International conference proceedings
- Nov. 2016, Proceedings of the 5th International Conference on Human-Environment System, 20157, 1 - 8, EnglishHygrothermal analysis of bedroom of dwelling house in winter[Refereed]International conference proceedings
- Nov. 2016, Proceedings of the 5th International Conference on Human-Environment System, 20155, 1 - 10, EnglishAnalysis of heat and moisture transfer around the human body considering ventilation in the air layer of clothing[Refereed]International conference proceedings
- Jul. 2016, Proceedings of 4th International Conference on Archi-Cultural Interactions through the Silk Road, 186 - 189, EnglishMoisture evaporation from eyes and prevention of sensation of dryness under low indoor humidity[Refereed]International conference proceedings
- Jul. 2016, Proceedings of 4th International Conference on Archi-Cultural Interactions through the Silk Road, 190 - 193, EnglishInfluence of ventilation in the air layer of clothing on heat and moisture transfer around the human body[Refereed]International conference proceedings
- Jul. 2016, Proceedings of 4th International Conference on Archi-Cultural Interactions through the Silk Road, 194 - 197, EnglishAnalysis of temperature and humidity in the bedroom of a Japanese dwelling house in winter[Refereed]International conference proceedings
- Apr. 2016, BUILDING AND ENVIRONMENT, 99, 210 - 220, English[Refereed]Scientific journal
- Elsevier Ltd, Nov. 2015, Energy Procedia, 78, 1495 - 1500, English[Refereed]International conference proceedings
- 2015, 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 78, 1495 - 1500, English[Refereed]International conference proceedings
- Architectural Institute of Japan, 2015, Journal of Environmental Engineering (Japan), 80(715) (715), 731 - 740, English[Refereed]Scientific journal
- 2015, 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 78, 2712 - 2716, English[Refereed]International conference proceedings
- Lead, 2015, 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 78, 2772 - 2777, English[Refereed]International conference proceedings
- Under conditions without sweating, the transient responses of skin (stratum corneum) moisture content to the stepwise change in the absolute humidity around the skin were measured at the forearm by the electrostatic capacity method and by in vivo confocal Raman spectroscopy. As the results of the measurement by the electrostatic capacity method, it was shown that the skin moisture content showed vivid response to the stepwise change in ambient absolute humidity, and that the response almost converges within 5-10 min in case of the exposure to high (80 %rh) and low (10 %rh) humidity for 30 min. In addition, as the results of the measurement by in vivo confocal Raman spectroscopy, the distribution of moisture content in the stratum corneum responding to the stepwise changes of ambient absolute humidity was obtained, and it was shown that the moisture content in the region deeper than 30μm was almost constant, and that the moisture content in the region shallower than 10-16μm changed due to the exposure to high (90 %rh) and low (10 %rh) humidity for 30 min.Japanese Society of Human-Environment System, Nov. 2014, Journal of human and living environment, 21(2) (2), 67 - 74, Japanese[Refereed]Scientific journal
- Lead, Nov. 2014, Journal of the Human-Environment System, 17(1) (1), 25 - 32, English[Refereed]Scientific journal
- A methodology was proposed to determine the distribution of thickness of air layer in clothing based on the shape data of human body and clothing measured by a 3D laser scanner. By using the methodology, the vertical distribution of thickness of air layer was determined and its characteristics were grasped quantitatively for the case of young male individuals wearing a shirt in the standing posture. It was shown that the air layer is thick at the waist, and its thickness is almost zero around the shoulder not depending on the differences in the aspect of dressing, in the physique, and in the kind of the clothing. In addition, for the case of wearing suit (wearing clothing one over another), the vertical distribution of thickness between two sheets of clothing as well as between skin and clothing was determined. The possibility of determining the distribution of heat and moisture transfer resistance in the air layer based on the thickness was suggested to evaluate the local effect by the air layer formed by clothing on the thermophysiological responses.Lead, Japanese Society of Human-Environment System, May 2014, Journal of human and living environment, 21(1) (1), 1 - 7, Japanese[Refereed]Scientific journal
- Architectural Institute of Japan, 2014, Journal of Environmental Engineering (Japan), 79(697) (697), 233 - 239, Japanese[Refereed]Scientific journal
- Lead, Oct. 2013, BUILDING AND ENVIRONMENT, 68, 123 - 133, English[Refereed]Scientific journal
- Lead, Apr. 2013, JOURNAL OF BUILDING PHYSICS, 36(4) (4), 422 - 437, English[Refereed]Scientific journal
- Lead, Architectural Institute of Japan, 2013, Journal of Environmental Engineering (Japan), 78(693) (693), 835 - 840, Japanese[Refereed]Scientific journal
- Aug. 2012, Proceedings of the 9th International Meeting for Manikins and Modeling (9i3m), Tokyo, Japan, No. 15, EnglishCFD analysis on ventilation in air layer in clothing considering real shape of the human bodyInternational conference proceedings
- May 2012, Proceedings of the 5th international Building Physics Conference (IBPC), Kyoto, Japan, pp.939-944, EnglishTransient response of skin surface moisture content to change in indoor humidity, Measurement and modeling of moisture transfer in skin surface[Refereed]International conference proceedings
- May 2012, Proceedings of the 5th international Building Physics Conference (IBPC), Kyoto, Japan, pp.959-964, EnglishThermal physiological response to local heating and cooling during sleep[Refereed]International conference proceedings
- May 2012, Proceedings of the 5th international Building Physics Conference (IBPC), Kyoto, Japan, pp.953-958, EnglishModeling of moisture evaporation from skin, eye and airway for evaluating sensation of dryness under low humidity environment[Refereed]International conference proceedings
- May 2012, Proceedings of the 5th international Building Physics Conference (IBPC), Kyoto, Japan, pp.981-987, EnglishEffect of posture on thermal regulation of human body during sleep, Experiment involving awaken subjects[Refereed]International conference proceedings
- Mar. 2012, Journal of Environmental Engineering, 77(673) (673), 115 - 120, Japanese[Refereed]Scientific journal
- Mar. 2012, 日本建築学会環境系論文集, vol. 77, No. 673, pp. 115-120, Japanese加圧煙制御における常温換気計算法に基づ給気量算定法および空気逃し開口部の設置高さの影響[Refereed]Scientific journal
- Higher Education Press Limited Company, Mar. 2012, Frontiers of Architectural Research, 1(1) (1), 51 - 57, English[Refereed]Scientific journal
- 2012, Proceedings of the 9th International Meeting for Manikins and Modeling, pp.70-75A model of heat and moisture transfer in and around clothing, coupled with a human thermal model for the analysis of the transient state, including the process of sweat evaporationInternational conference proceedings
- Dec. 2011, Japanese Journal of Perspiration Research, Vol.18, No.2, pp.66-70, Japanese人体熱モデルによる発汗時の数値シミュレーションScientific journal
- Oct. 2011, Proceedings of the Fourth International Conference on Human-Environment System, Sapporo, Japan, pp.241-246, EnglishStudy on prediction of thermal sensation in non-steady state proposal of equation and its applicable range[Refereed]International conference proceedings
- Oct. 2011, Proceedings of the Fourth International Conference on Human-Environment System, Sapporo, Japan, pp.277-282, EnglishResponse of skin surface moisture to change in indoor temperature and humidity[Refereed]International conference proceedings
- Oct. 2011, Proceedings of the Fourth International Conference on Human-Environment System, Sapporo, Japan, pp.271-276, EnglishPrediction of evaporation rate from the skin, eyes and airway to evaluate sensation of dryness in a low humidity environment[Refereed]International conference proceedings
- Oct. 2011, Proceedings of the Fourth International Conference on Human-Environment System, Sapporo, Japan, pp.103-108, EnglishAnalysis of heat, air and moisture transfer in air layer in clothing based on 3D shape data[Refereed]International conference proceedings
- Lead, Mar. 2011, BUILDING AND ENVIRONMENT, 46(3) (3), 597 - 604, English[Refereed]Scientific journal
- Mar. 2010, INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 54(2) (2), 165 - 178, English[Refereed]Scientific journal
- 2010, Journal of Environmental Engineering, 75(658) (658), 1051 - 1060, Japanese[Refereed]Scientific journal
- Sep. 2009, BUILDING AND ENVIRONMENT, 44(9) (9), 1777 - 1787, English[Refereed]Scientific journal
- Vapour pressure decreases and moisture movement gets slower in clothing with an increasing concentration of the main impurity of sweat, namely sodium chloride. Then the evaporation rate of water at the surface of clothing differs from those of pure water. In the previous paper, the simultaneous heat, moisture and salt transfer model was proposed and validated to quantify such influences of salt on the heat and moisture transfer. In this paper, the influence of salt on the hygrothermal properties of clothing (i.e. cotton) around a human body with a constant temperature is numerically analysed with the model proposed. First the evaporation of water in clothing which contains saturated salt water is compared to that of pure water to assess how significant the influence of salt can become after several processes of the absorption and evaporation of sweat. Secondly the movement and accumulation of salt in clothing under cyclic sweating is investigated. It is concluded that the accumulated salt reduces the evaporation rate and the simultaneous latent heat loss at the exterior surface of the clothing, so the temperature decrease of the clothing due to sweat is reduced and the subsequent temperature increase is delayed. It is also shown that the salt distribution in the clothing extremely depends on the effective diffusion coefficient of salt, which ultimately influences the evaporation rate at the exterior surface of the clothing and the corresponding temperature and humidity in the clothing.The Society of Heating, Air-Conditioning & Sanitary Engineers of Japan, May 2009, Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Vol. 146, pp.35-43(146) (146), 35 - 43, Japanese[Refereed]Scientific journal
- Lead, Mar. 2009, BUILDING AND ENVIRONMENT, 44(3) (3), 463 - 470, English[Refereed]Scientific journal
- Feb. 2009, Journal of Environmental Engineering, 74(636) (636), 141 - 149, Japanese[Refereed]Scientific journal
- Architectural Institute of Japan, 2009, Journal of Environmental Engineering, 74(645) (645), 1195 - 1202, Japanese[Refereed]Scientific journal
- Architectural Institute of Japan, 2009, Journal of Environmental Engineering, 74(645) (645), 1203 - 1209, Japanese[Refereed]Scientific journal
- Nov. 2008, 2008 Korea-Japan Joint Conference on Wellness @ Living Environment, Cheju, Korea, pp.9-12, EnglishIndividual difference in transient thermophysiological responses to change in air temperature, A study based on subject experiments for sedentary caseInternational conference proceedings
- Jun. 2008, Proceedings of 8th Nordic Symposium on Building Physics, 307-314, EnglishSimultaneous heat, moisture and salt transfer in clothing[Refereed]International conference proceedings
- Accumulated salt-the main impurity of sweat-in clothing can have significant influences on the transport of heat and moisture: the more concentrated salt water is, the lower the vapour pressure of water; it also affects the liquid water transfer. The former report of this research experimentally demonstrated that salt water penetrates more slowly than pure water, which corresponds to the fact that salt lowers the chemical potential of water. This paper shows the numerical model of heat, moisture and salt transfer in cloth in order to quantify the salt influences on the heat and moisture transfer. The experimental data provided in the former report are numerically analysed with the model proposed here and it was shown that the numerical analysis with the model implemented can reasonably explain the heat and moisture transfer in the cloth which contains salt in it.The Society of Heating, Air-Conditioning & Sanitary Engineers of Japan, Feb. 2008, Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, No.131,pp.1-10(131) (131), 1 - 9, Japanese[Refereed]Scientific journal
- Lead, Oct. 2007, JOURNAL OF BUILDING PHYSICS, 31(2) (2), 125 - 142, English[Refereed]Scientific journal
- Oct. 2007, Proceedings of Indoor Air Quality Ventilation & Energy Conservation in Buildings (IAQVEC 2007), Sendai, Japan, Vol. I, pp.867-874, EnglishDescription of individual difference in human body temperature regulation by using two-node model[Refereed]International conference proceedings
- Sweat is important for the thermal response of human body in the thermal environment. It is dealt with as pure water when the influence of sweat on the human body temperature is studied in the prediction and evaluation of the thermal comfortability of the environment. However sweat is salt water with low concentration in reality. Not only does salt change the vapour pressure of the water, it may also affect the permeability of water in cloth because of the blocking of water movement by salt These influences of salt on the heat and moisture transfer in cloth can be considered to become unignorable when the salt accumulates in the cloth through several sweating and drying processes. The former part of this paper reports on experiments of pure or salt water uptake, using sodium chloride that is the main impurity of sweat. Experimental results show that salt water penetrates into the cloth at a lower speed than pure water. The latter part shows the model of absorption isotherm of cloth considering salt influences and gives some qualitative explanation for the result of experiments with the use of this model.The Society of Heating, Air-Conditioning & Sanitary Engineers of Japan, Feb. 2007, Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, No.119,pp.17-22(119) (119), 17 - 22, Japanese[Refereed]Scientific journal
- Jan. 2007, Journal of ASTM International, 4(1) (1), English[Refereed]Scientific journal
- 2007, HEAT-AIR-MOISTURE TRANSPORT: MEASUREMENTS ON BUILDING MATERIALS, 1495, 101 - 111, EnglishThe effect of vertical distribution of water permeability on the modeled neutralization process in concrete walls[Refereed]International conference proceedings
- 2007, BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, pp.725-731, 725 - +, EnglishThermal model of human body temperature regulation considering individual difference[Refereed]International conference proceedings
- In this study, a transient rise in core temperature during cooling after being in a hot environment is measured in a naked subject. After performing exercise for 30 minutes in an ambient temperature of 35℃, the subject was seated and allowed to rest for 60 minutes in an air-conditioned room maintained at 26℃. A transient rise in the rectal temperature was observed at the beginning of the rest. To clarify the influence that the skin and muscle blood flow have on the core temperature, the measured results were analyzed using the Stolwijk model. This analysis gave results that during the initial 3 minutes of rest, skin blood flow showed a significant drop caused by a decrease in the mean skin temperature. The transient rise in the core temperature is thought to be due to a significant reduction in the heat loss from the core to the relatively cool skin, which is caused by a decrease in skin blood flow.Architectural Institute of Japan, Nov. 2006, 日本建築学会環境系論文集, 609・23-30(609) (609), 23 - 30, Japanese[Refereed]Scientific journal
- 2006, RESEARCH IN BUILDING PHYSICS AND BUILDING ENGINEERING, pp. 209-216, 209 - 216, EnglishInfluences of acid rain on the neutralization process[Refereed]International conference proceedings
- 2006, Research in Building Physics and Building Engineering, pp. 775-781, 775 - 781, EnglishIndoor climate for comfortable sleep, considering heat and moisture transfer between the room, bedding and human body: Air control system using a predictive model for thermal comfort[Refereed]International conference proceedings
- In order to evaluate influences of rain on carbonation process of concrete structure, an analytical model was proposed for predicting carbonation process coupled with heat and moisture transfer, particularly liquid movement. The accelerated carbonation experiment under the isothermal condition in a literature was simulated by using the proposed model, in which the coefficients of moisture transfer and CO_2 diffusion were estimated by comparing the simulation results with the experimental results. By using the coefficients corresponding to the water cement ratio and the curing condition, this model can predict carbonation progress well. The simulation results also showed that the liquid transfer significantly influenced the carbonation process even under the rainless condition such as evaporating process after placing.Architectural Institute of Japan, Sep. 2005, 日本建築学会構造系論文集, 第595号, pp.17-23(595) (595), 17 - 23, Japanese[Refereed]Scientific journal
- Sep. 2004, Proceedings CIB W40 meeting, Glasgow, UK,, EnglishEnvironmental control for comfortable sleeping, considering both physiological responses of human body and influence of heat and moisture transfer in beddingInternational conference proceedings
- In this study, numerical analysis by using a thermoregulation model of the human body and subject experiment were carried out in order to examine the physiological response to partial cooling of the human body in a warm environment. Differences in physiological response were analyzed by comparing cooling of the head, trunk and extremities. In each case, heat loss was loaded for equal areas of skin. When the head was cooled, total heat loss from the whole body was less and mean skin temperature and mean body temperature were higher, than when the trunk or extremities were cooled. This was because of the decrease in thermal evaporation mainly caused by a decrease in head core temperature. From this analysis, it was assumed that greater heat loss is expected when cooling body parts other than the head, if the degree of cooling is equal. This hypothesis was supported by physiological responses observed in an experimental subject, whose feet or head were cooled by blowing cold air.Last, Japanese Society of Biometeorology, Aug. 2004, 日本気象学会雑誌, Vol.41,№1,19-30(1) (1), 19 - 30, Japanese[Refereed]Scientific journal
- In order to clarify the influence of air flow between skin and clothing by natural convection on heat and moisture transfer around human body, the air distribution around human body is analyzed by using CFD for a simplified model of human body and clothing. By inputting the air flow rate through the air layer and convective heat transfer coefficients from skin to air layer and from clothing to air layer obtained by CFD analysis, the heat and moisture behavior around human body is analyzed by the model of human thermal system combined with simultaneous heat and moisture transfer model for clothing. The influence of thc air flow through the air layer between skin and clothing is not significant when the thickness of air layer is less than 0.5 cm. When the thickness of the air layer is 1 cm, the influence of the air flow on heat and moisture transfer should be properly taken into account.Last, Architectural Institute of Japan, Jun. 2004, 日本建築学会計画系論文集, 第580号,23-30(580) (580), 23 - 29, Japanese[Refereed]Scientific journal
- Lead, Feb. 2004, Jounal of the Human-environment System, Vol.7,№1,29-34, English[Refereed]Scientific journal
- Various models on human thermal system have been proposed. The characteristics of each model are summarized in this paper. It is shown that all the models essentially consist of heat balance equations for human body represented as several nodes and that the temperature regulation responses (blood flow, sweating, shivering) are described by the functions of deviation of skin and core temperatures from respective reference temperature. An example of comparison between the calculated results by a model of human thermal system and the experimental results are shown, and the problems in predicting the temperature regulation response by models are pointed out to describe the outlook for the future work and the application of the models.Japanese Society of Biometeorology, 2003, Japanese journal of biometeorology, 40(4) (4), 225 - 234, Japanese
- 2003, ASHRAE Transactions, Vol.109,Part1,CH-03-2-2, EnglishInfluence of air exchange through small openings between rooms[Refereed]Scientific journal
- This study was carried out in order to construct a model to predict thermal sensation in thermal transients, by examining the relation between thermal sensation vote and physiological data related to thermoreception obtained by subject experiments. A regression model consisting of five variables, mean skin temperature and its time derivative, temperature of tympanum and its time derivative, and heat flux at'skin surface, was used to describe thermal sensation vote in thermal transients. When four different sets of regression coefficients were given in accordance with the heat flux at skin surface, which was considered to represent degree of thermal transients, the time series of calculated thermal sensation agreed with the thermal sensation vote. It was thus shown that thermal sensation in thermal transients could be predicted by the model proposed in this paper.Architectural Institute of Japan, Jan. 2003, Journal of architecture,planning and environmental engineering. Transactions of AIJ, 第563号, pp.9-15(563) (563), 9 - 15, Japanese[Refereed]Scientific journal
- Sep. 2002, 睡眠と環境, 第6巻第1号, pp.71-77, Japanese寝具における熱水分移動とその人体温熱生理応答への影響[Refereed]Scientific journal
- Lead, Sep. 2002, 睡眠と環境, 第6巻第1号, pp.62-70, JapaneseTwo-Node Modelにおける発汗調節モデルの検討[Refereed]Scientific journal
- 2002, Journal of Asian Architecture and Building Engineering, 1(2) (2), 79 - 86, English[Refereed]Scientific journal
- A subject experiment was conducted to measure the transient response of a clothed human body during sweating and its evaporation. The result of the experiment was analyzed by a combined model, which consists of the two-node model for thermophysiological response of human body and the simultaneous heat and moisture transfer model for hygrothermal behavior of clothing. In that model, the heat and moisture transfer through the air layer between the skin and the clothing are expressed as heat and moisture conductances, respectively. The conductances along with the other parameters related to the heat andmoisture transfer in and a round the clothing were determined to show an agreement with the subject experiment.Lead, Architectural Institute of Japan, Nov. 2001, Journal of architecture,planning and environmental engineering. Transactions of AIJ, 第549号, pp.23-30(549) (549), 23 - 30, Japanese[Refereed]Scientific journal
- Sep. 2001, 7th REHVA World Congress CLIMA 2000/Napoli 2001, Napoli, Italy, EnglishAdaptability of Thermophysiological Model of Human Body to Non-Steady State in Sweating and Evaporation Process[Refereed]International conference proceedings
- Apr. 2001, Proceedings CIB W40 meeting, Wellington, New Zealand, EnglishMeasurement of Moisture Conductivity of ClothingInternational conference proceedings
- Apr. 2001, Proceedings CIB W40 meeting, Wellington, New Zealand, EnglishHeat and Moisture Transfer in Bed and its Influence on Human Thermo-Physiological ResponsesInternational conference proceedings
- 2001, ASHRAE Transactions, Vol. 107, Part 1, 4418, pp.71-, EnglishPrediction of skin and clothing temperatures under thermal transient considering moisture accumulation in clothing[Refereed]Scientific journal
- Sep. 1999, Proceedings CIB W40 meeting, Prague, Czech, pp.69-74, EnglishMoisture Movement in Clothing under GravityInternational conference proceedings
- Sep. 1999, Proceedings CIB W40 meeting, Prague, Czech, pp.87-92, EnglishInfluence of Crack on Heat and Moisture Transfer in Concrete WallInternational conference proceedings
- Sep. 1999, Proceedings of Building Simulation ’99, Kyoto, Japan, EnglishEffect of Sweat Accumulation in Clothing on Transient Thermophysiological Response of Human Body to the Environment[Refereed]International conference proceedings
- Aug. 1999, Indoor Air 99, Edinburgh, EnglishEffect of Sweat Movement and Accumulation in Clothing on the Body Temperature Regulation System[Refereed]International conference proceedings
- Lead, 1999, Journal of the Human-Environment System, Vol.2, No.1, pp.57-67(1) (1), 57 - 67, English[Refereed]Scientific journal
- Lead, 日本熱物性研究会, Jul. 1998, Netsu Bussei, 12巻3号, pp.120-125(3) (3), 120 - 125, JapaneseDetermination of water diffusivity of cloth[Refereed]Scientific journal
- Oct. 1997, Proceedings CIB W40 meeting, Kyoto, Japan, pp.277-290, EnglishHeat and Moisture Movement in ClothesInternational conference proceedings
- Mar. 1997, Journal of architecture,planning and environmental engineering. Transactions of AIJ, 第493号, pp.39-45, 39 - 46, Japanese地盤蓄熱性状への地下水流の影響について 年周期蓄熱媒体としての地盤利用に関する研究(その3)[Refereed]Scientific journal
- Jun. 1996, Proceedings 7th International Conference on Thermal Energy Storage, Sapporo, Japan, pp.25-30, EnglishAn Analysis of the Thermal Behavior of the Ground for Annual Ground Heat Storage[Refereed]International conference proceedings
- Sep. 1995, Proceedings International Symposium on Moisture Problems in Building Walls, Porto, Portugal, pp.492-501, EnglishAn Analysis of the Earth Ground Heat Storage Process -The Effects of Ground Water Flow-International conference proceedings
- Mar. 1995, Proceedings Pan Pacific Symposium on Building and Urban Environmental Conditioning in Asia, Nagoya, Japan, pp.125-134, EnglishA Study on Earth Ground Heat Storage -Numerical Analysis of Ground Water-International conference proceedings
- 人間-生活環境系シンポジウム実行委員会, 09 Dec. 2017, 人間-生活環境系シンポジウム報告集 = Proceedings of Symposium on Human-Environment System, 41, 99 - 102, Japanese住宅全館の熱水分移動解析による非暖房室における結露性状の予測
- 01 Nov. 2017, 病院設備, 59(6) (6), 136, Japanese寒冷地の高齢者介護施設における給湯・温水エネルギー消費調査
- 01 Nov. 2017, 病院設備, 59(6) (6), 135, Japanese寒冷地の高齢者介護施設における室内温熱環境の調査
- 20 Jul. 2017, 日本建築学会大会学術講演梗概集・建築デザイン発表梗概集(CD-ROM), 2017, ROMBUNNO.40286, Japanese高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の定量的評価 その2 エネルギー使用内訳と温水暖房・浴槽昇温系統における結果の考察
- 20 Jul. 2017, 日本建築学会大会学術講演梗概集・建築デザイン発表梗概集(CD-ROM), 2017, ROMBUNNO.40285, Japanese高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の定量的評価 その1 調査概要と給湯系統消費エネルギーの算定
- 20 Jul. 2017, 日本建築学会大会学術講演梗概集・建築デザイン発表梗概集(CD-ROM), 2017, ROMBUNNO.41086, Japanese高齢者介護施設の室内温熱環境に関する研究(その1)熱・空気環境の実測調査と改善策
- 20 Jul. 2016, 日本建築学会大会学術講演梗概集・建築デザイン発表梗概集(CD-ROM), 2016, ROMBUNNO.41223, Japanese冬季における寝室の温湿度環境改善に関する研究(その2)室内温湿度解析における実態に即した計算条件の検討
- 20 Jul. 2011, 学術講演梗概集. D-2, 環境工学II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換気・排煙, 数値流体, 空気清浄, 暖冷房・空調, 熱源設備, 設備応用, 2011, 99 - 100, Japanese41050 局所冷暖房に対する睡眠時の温熱生理反応(人体熱モデルによる評価,環境工学II)
- 20 Jul. 2011, 学術講演梗概集. D-2, 環境工学II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換気・排煙, 数値流体, 空気清浄, 暖冷房・空調, 熱源設備, 設備応用, 2011, 103 - 104, Japanese41052 人体熱モデルを用いた入浴時の温熱生理反応の解析(人体熱モデルによる評価,環境工学II)
- 25 May 2011, 日本建築学会近畿支部研究報告集. 環境系, (51) (51), 285 - 288, Japanese4072 局所冷暖房に対する睡眠時の温熱生理反応(環境)
- 20 Jul. 2010, 学術講演梗概集. D-2, 環境工学II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換気・排煙, 数値流体, 空気清浄, 暖冷房・空調, 熱源設備, 設備応用, 2010, 543 - 544, Japanese41272 睡眠時の快適な温熱環境の形成に関する研究 : その3 入浴前から起床に至る過程の実験と解析(住宅・睡眠,環境工学II)
- 社団法人空気調和・衛生工学会, 01 Mar. 2005, 支部学術研究発表会前刷集, (16) (16), 53 - 56, JapaneseA-14 住宅厨房のIH調理機器に適した排気システム及びキッチン形態に関する研究:温度測定による気流性状の把握および数値計算
- Joint work, 日本建築学会, Mar. 2021Standard for Diagnosing Moisture Damage in Buildings and Implementing Countermeasures
- Joint work, Architectural Institute of Japan, Mar. 2020Standard for Measurement of Moisture Properties
- Joint work, Architectural Institute of Japan, May 2019, EnglishScholarly book
- Joint work, 技報堂出版, Oct. 2015, Japanese, ISBN: 9784765525831心理と環境のデザイン-感覚・知覚の実践-Scholarly book
- Joint work, 日本建築学会, Feb. 2015, Japanese, ISBN: 9784818936256サーマルマネキンを用いた室内温熱環境評価法規準・同解説Scholarly book
- Others, 日本建築学会, Feb. 2013, Japanese建物における湿害の診断と対策に関する規準・同解説Scholarly book
- Joint work, 日本建築学会, Mar. 2011, Japanese建築環境工学用教材 環境編Textbook
- Joint work, 日本建築学会, Mar. 2011, Japanese建築環境工学実験用教材Textbook
- Joint work, 朝倉書店, Apr. 2010, Japaneseからだと温度の事典Scholarly book
- Joint work, 丸善, Sep. 2009, Japanese現代住宅研究の変遷と展望Scholarly book
- Joint work, Architectural Institute of Japan, Mar. 2008, Japanese, ISBN: 9784818936065Academic Standards for Measurement of Indoor Thermal EnvironmentsScholarly book
- Joint work, 日本建築学会, Jan. 2006, Japanese湿気物性に関する測定規準・同解説Scholarly book
- Joint work, 日本建築学会, Oct. 2001, Japanese建築材料の熱・空気・湿気物性値Scholarly book
- 第43回人間-生活環境系シンポジウム, Nov. 2019, Japanese, 人間-生活環境系学会, 釧路, Domestic conference低湿度環境における眼表面の状態と乾燥による不快感に関する研究 ―コンタクトレンズ装用者と非装用者の比較―Oral presentation
- 第43回人間-生活環境系シンポジウム, Nov. 2019, Japanese, 人間-生活環境系学会, 釧路, Domestic conference局所皮膚温を用いた全身温冷感予測の可能性Oral presentation
- 第43回人間-生活環境系シンポジウム, Nov. 2019, English, 人間-生活環境系学会, 釧路, Domestic conferenceAnalysis of Hygrothermal Behavior of Underground Space Influence of Moisture Condition of Ground on the Indoor HumidityOral presentation
- 第43回人間-生活環境系シンポジウム, Nov. 2019, Japanese, 人間-生活環境系学会, 釧路, Domestic conference皮膚表面からの不感蒸泄による水分損失量と皮膚における水分収支に関する研究Oral presentation
- 空気調和・衛生工学会近畿支部環境工学研究会, Oct. 2019, Japanese, 空気調和・衛生工学会近畿支部環境工学研究会, 大阪, Domestic conference温冷感申告における個人差の検討-温冷感の予測に向けてInvited oral presentation
- 空気調和・衛生工学会学術講演会, Sep. 2019, Japanese, 空気調和・衛生工学会, 北海道科学大学, Domestic conference高層ビルのエレベーターにおける煙突効果の防止策(第2報)エレベーターシャフトに設ける自然換気口の設計手法の検討Oral presentation
- 空気調和・衛生工学会学術講演会, Sep. 2019, Japanese, 空気調和・衛生工学会, 北海道科学大学, Domestic conference高層ビルのエレベーターシャフトにおける煙突効果の防止策(第1報)換気計算によるエレベーター扉前後の差圧の再現Oral presentation
- 日本建築学会大会学術講演会, Sep. 2019, Japanese, 日本建築学会, 金沢工業大学, Domestic conference高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の評価 その4 年間のエネルギー消費傾向と熱源の運転制御改善方策の検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2019, Japanese, 日本建築学会, 金沢工業大学, Domestic conference高齢者介護福祉施設の室内温熱環境に関する研究(その3)建物全体の換気性状の解析Oral presentation
- 日本建築学会大会学術講演会, Sep. 2019, Japanese, 日本建築学会, 金沢工業大学, Domestic conference物性値のばらつきが熱水分同時移動の解析結果に及ぼす影響 ALC の物性値一式の測定および既往の値との比較Oral presentation
- 日本建築学会大会学術講演会, Sep. 2019, English, 日本建築学会, 金沢工業大学, Domestic conferenceComparative study of two hygrothermal analysis methods in hygroscopic regionOral presentation
- 日本建築学会大会学術講演会, Sep. 2019, 日本建築学会, 金沢工業大学, Domestic conference低湿度環境下での乾燥感に関する研究 (その 15)眼球における熱水分移動モデルと眼の乾燥感の非定常応答の予測Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2019, Japanese, 日本建築学会, 大阪, Domestic conference物性値のばらつきが熱水分同時移動の解析結果に及ぼす影響 ALC 物性値一式の測定と既往の値との比較Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2019, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その15)眼球における熱水分移動モデルと眼の乾燥感の非定常応答の予測Oral presentation
- 空気調和・衛生工学会近畿支部近畿支部学術研究発表会, Mar. 2019, Japanese, The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Osaka University Nakanoshima Center, Domestic conference半地下空間における結露性状の解析(その2)夏期及び冬期における結露の対策Oral presentation
- 空気調和・衛生工学会近畿支部近畿支部学術研究発表会, Mar. 2019, Japanese, The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Osaka University Nakanoshima Center, Domestic conference半地下空間における結露性状の解析(その1)地盤と接する室の熱湿気性状の把握Oral presentation
- シンポジウム 多角的な視点から見た今後の外皮性能のあり方, Mar. 2019, Japanese, Architectural Institute of Japan, Kenchiku Kaikan, Domestic conference湿気環境から見た外皮性能Oral presentation
- 空気調和・衛生工学会近畿支部近畿支部学術研究発表会, Mar. 2019, Japanese, The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Osaka University Nakanoshima Center, Domestic conference眼の乾燥感の低湿度に対する非定常応答-眼球表面での熱水分移動に基づく検討-Oral presentation
- 第42回人間-生活環境系シンポジウム, Dec. 2018, Japanese, Japanese Society of Human-Environment System, Setsunan University, Domestic conference非定常温冷感予測に関する研究―非定常状態における全身と局所の評価構造の差異―Oral presentation
- 第42回人間-生活環境系シンポジウム, Dec. 2018, Japanese, Japanese Society of Human-Environment System, Setsunan University, Domestic conference半地下空間における結露性状に関する研究-地盤内水分の影響を考慮した解析モデルによる対策の検討-Oral presentation
- 第42回人間-生活環境系シンポジウム, Dec. 2018, Japanese, Japanese Society of Human-Environment System, Setsunan University, Domestic conference低湿度条件下での乾燥感に関する被験者実験Oral presentation
- 第42回人間-生活環境系シンポジウム, Dec. 2018, Japanese, Japanese Society of Human-Environment System, Setsunan University, Domestic conference高齢者介護福祉施設の室内環境の改善に関する研究―居住状態の建物における多数室換気解析―Oral presentation
- 第42回人間-生活環境系シンポジウム, Dec. 2018, Japanese, Japanese Society of Human-Environment System, Setsunan University, Domestic conference眼の乾燥感の予測に向けた涙の蒸発・蓄積のモデリングOral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第48回熱シンポジウム, Oct. 2018, Japanese, Architectural Institute of Japan, Kyoto University, Domestic conference熱湿気物性値の集積状況と数値計算における問題点Oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第48回熱シンポジウム, Oct. 2018, Japanese, Architectural Institute of Japan, Kyoto University, Domestic conference低湿度曝露時における被験者の心理反応と健康Oral presentation
- 日本建築学会大会学術講演会, Sep. 2018, Japanese, Architectural Institute of Japan, Tohoku University, Domestic conference非定常温冷感予測に関する研究(その5)全身温冷感予測式を用いた局所温冷感予測の可能性Oral presentation
- 日本建築学会大会学術講演会, Sep. 2018, Japanese, Architectural Institute of Japan, Tohoku University, Domestic conference低湿度環境下での乾燥感に関する研究(その14)乾燥感の評価構造の解明に向けた被験者実験Oral presentation
- 日本建築学会大会学術講演会, Sep. 2018, Japanese, Architectural Institute of Japan, Tohoku University, Domestic conference地下空間における湿害の対策に関する研究 壁体の吸放湿を考慮した解析モデルによる検討Oral presentation
- 空気調和・衛生工学会大会, Sep. 2018, Japanese, The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Daido University, Domestic conference室内湿度の下限値に関する研究 被験者実験による低湿度に対する心理反応の検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2018, Japanese, Architectural Institute of Japan, Tohoku University, Domestic conference高齢者介護福祉施設の室内温熱環境に関する研究(その2)換気方式の変更による室内環境の改善策Oral presentation
- 日本建築学会大会学術講演会, Sep. 2018, Japanese, Architectural Institute of Japan, Tohoku University, Domestic conference高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の評価(その3) 年間のエネルギー消費傾向と給湯系統の配管熱損失の調査Oral presentation
- 日本建築学会大会学術講演会, Sep. 2018, Japanese, Architectural Institute of Japan, Tohoku University, Domestic conference気流感を低減させるエアコンの暖房制御方法の開発Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2018, Japanese, Architectural Institute of Japan, Osaka Health Science University, Domestic conference非定常温冷感予測に関する研究(その5)全身温冷感予測式を用いた局所温冷感予測の可能性Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2018, Japanese, Architectural Institute of Japan, Osaka Health Science University, Domestic conference低湿度環境下での乾燥感に関する研究(その14)乾燥感の評価構造の解明に向けた被験者実験Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2018, Japanese, Architectural Institute of Japan, Osaka Health Science University, Domestic conference地下空間における湿害の対策に関する研究 壁体の吸放湿を考慮した解析モデルによる検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2018, Japanese, Architectural Institute of Japan, Osaka Health Science University, Domestic conference高齢者介護福祉施設の室内温熱環境に関する研究(その2)換気方式の変更による室内環境の改善策Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2018, Japanese, Architectural Institute of Japan, Osaka Health Science University, Domestic conference高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の定量的評価 年間のエネルギー消費傾向と給湯系統の配管熱損失の調査Oral presentation
- 第41回人間-生活環境系シンポジウム, Dec. 2017, Japanese, 人間-生活環境系学会, 信州大学, Domestic conference非定常温冷感予測に関する研究―局所温冷感の特性と全身温冷感との関係―Oral presentation
- 第41回人間-生活環境系シンポジウム, Dec. 2017, Japanese, 人間-生活環境系学会, 信州大学, Domestic conference半地下空間における結露性状に関する研究-傾斜地に建つ集合住宅内の非居住状態での実測と解析-Oral presentation
- 第41回人間-生活環境系シンポジウム, Dec. 2017, Japanese, 人間-生活環境系学会, 信州大学, Domestic conference低湿環境における乾燥感の評価構造に関する研究Oral presentation
- 第41回人間-生活環境系シンポジウム, Dec. 2017, Japanese, 人間-生活環境系学会, 信州大学, Domestic conference着衣における熱水分移動・体温調節系・温冷感の解析モデルOral presentation
- 第41回人間-生活環境系シンポジウム, Dec. 2017, Japanese, 人間-生活環境系学会, 信州大学, Domestic conference住宅全館の熱水分移動解析による非暖房室における結露性状の予測Oral presentation
- 第46回日本医療福祉設備学会, Nov. 2017, Japanese, 第46回日本医療福祉設備学会, 東京・ビッグサイト, Domestic conference寒冷地の高齢者介護施設における室内温熱環境の調査Oral presentation
- 第46回日本医療福祉設備学会, Nov. 2017, Japanese, 第46回日本医療福祉設備学会, 東京・ビッグサイト, Domestic conference寒冷地の高齢者介護施設における給湯・温水エネルギー消費調査Oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第47回熱シンポジウム, Nov. 2017, Japanese, 日本建築学会, 東京・建築会館, Domestic conference温冷感申告における個人差と温冷感の予測Oral presentation
- 空気調和・衛生工学会大会, Sep. 2017, Japanese, 空気調和・衛生工学会, 高知工科大学, Domestic conference低湿度条件下での眼の乾燥感に関する研究 眼の状態と温熱環境条件の関係Oral presentation
- 空気調和・衛生工学会大会, Sep. 2017, Japanese, 空気調和・衛生工学会, 高知工科大学, Domestic conferenceサーマルマネキンを用いた温熱環境評価法に関する研究(第5報)温冷感申告値の各部位における差異Oral presentation
- 空気調和・衛生工学会大会, Sep. 2017, Japanese, 空気調和・衛生工学会, 高知工科大学, Domestic conferenceサーマルマネキンを用いた温熱環境評価法に関する研究(第4報)高齢被験者を含む実験による個人差の要因の検討Oral presentation
- 日本建築学会大会学術講演会, Aug. 2017, Japanese, 日本建築学会, 広島工業大学, Domestic conference非定常温冷感予測に関する研究(その4)平均皮膚温と全身温冷感における個人差の検討Oral presentation
- 日本建築学会大会学術講演会, Aug. 2017, Japanese, 日本建築学会, 広島工業大学, Domestic conference地盤が住宅の結露性状に及ぼす影響に関する研究(その2)地盤の熱容量がコンクリート壁体の吸放湿性状に及ぼす影響Oral presentation
- 日本建築学会大会学術講演会, Aug. 2017, Japanese, 日本建築学会, 広島工業大学, Domestic conference高齢者介護施設の室内温熱環境に関する研究(その1)熱・空気環境の実測調査と改善策Oral presentation
- 日本建築学会大会学術講演会, Aug. 2017, Japanese, 日本建築学会, 広島工業大学, Domestic conference高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の定量的評価 その2 エネルギー使用内訳と温水暖房・浴槽昇温系統における結果の考察Oral presentation
- 日本建築学会大会学術講演会, Aug. 2017, Japanese, 日本建築学会, 広島工業大学, Domestic conference高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の定量的評価 その1 調査概要と給湯系統消費エネルギーの算定Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2017, Japanese, 日本建築学会, 大阪保健医療大学, Domestic conference非定常温冷感予測に関する研究(その4)平均皮膚温と全身温冷感における個人差の検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2017, Japanese, 日本建築学会, 大阪保健医療大学, Domestic conference地盤が住宅の結露性状に及ぼす影響に関する研究(その2)地盤の熱容量がコンクリート壁体の吸放湿性状に及ぼす影響Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2017, Japanese, 日本建築学会, 大阪保健医療大学, Domestic conference高齢者介護施設の室内温熱環境に関する研究(その1)熱・空気環境の実測調査と改善策Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2017, Japanese, 日本建築学会, 大阪保健医療大学, Domestic conference高齢者介護施設における給湯・温水システムのエネルギー使用量と熱損失の定量的評価Oral presentation
- 日本建築学会環境工学委員会建築設備運営委員会第12回建築設備シンポジウム, Oct. 2016, Japanese, 日本建築学会, 東京・建築会館, Domestic conference乾燥感に配慮した室内温湿度の調整方法Oral presentation
- 空気調和・衛生工学会大会, Sep. 2016, Japanese, 空気調和・衛生工学会, 鹿児島大学, Domestic conferenceサーマルマネキンを用いた温熱環境評価法に関する研究(第3 報)全身温冷感の個人差に関する被験者実験Oral presentation
- 日本建築学会大会学術講演会, Aug. 2016, Japanese, 日本建築学会, 福岡, Domestic conference非定常温冷感予測に関する研究(その3)全身温冷感に個人差が生じる要因の検討Oral presentation
- 日本建築学会大会学術講演会, Aug. 2016, Japanese, 日本建築学会, 福岡, Domestic conference冬季における寝室の温湿度環境改善に関する研究(その 2)室内温湿度解析における実態に即した計算条件の検討Oral presentation
- 日本建築学会大会学術講演会, Aug. 2016, Japanese, 日本建築学会, 福岡, Domestic conference低湿度環境下での乾燥感に関する研究(その13)湿度を変えた場合の皮膚含水率分布の測定Oral presentation
- 日本建築学会大会学術講演会, Aug. 2016, Japanese, 日本建築学会, 福岡, Domestic conference地盤が住宅の結露性状に及ぼす影響に関する研究 斜面に建つ集合住宅での温湿度の実測と解析Oral presentation
- 日本建築学会大会学術講演会, Aug. 2016, Japanese, 日本建築学会, 福岡, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル(その8)着衣内空気層での換気を考慮した非定常解Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2016, Japanese, 日本建築学会, 大阪, Domestic conference非定常温冷感予測に関する研究(その3)全身温冷感に個人差が生じる要因の検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2016, Japanese, 日本建築学会, 大阪, Domestic conference冬季における寝室の温湿度環境改善に関する研究(その 2)室内温湿度解析における実態に即した計算条件の検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2016, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究(その13)湿度を変えた場合の皮膚含水率分布の測定Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2016, Japanese, 日本建築学会, 大阪, Domestic conference地盤が住宅の結露性状に及ぼす影響に関する研究 斜面に建つ集合住宅での温湿度の実測と解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2016, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル(その8)着衣内空気層での換気を考慮した非定常解Oral presentation
- 第39回人間-生活環境系シンポジウム, Nov. 2015, Japanese, 人間-生活環境系学会, 東京, Domestic conference皮膚含水率の変動特性と個体差に関する検討Oral presentation
- 第39回人間-生活環境系シンポジウム, Nov. 2015, Japanese, 人間-生活環境系学会, 東京, Domestic conference皮膚温変化率が全身温冷感に与える影響Oral presentation
- 第39回人間-生活環境系シンポジウム, Nov. 2015, Japanese, 人間-生活環境系学会, 東京, Domestic conference着衣内空気層での換気を考慮した人体周りの熱水分移動の非定常解析Oral presentation
- 第39回人間-生活環境系シンポジウム, Nov. 2015, Japanese, 人間-生活環境系学会, 東京, Domestic conference数値流体解析による着衣内空気層の部位別熱抵抗の算出Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference非定常温冷感予測に関する研究 (その1)皮膚温の部位差を考慮した全身温冷感予測モデルの検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference冬季における寝室の温湿度環境改善に関する研究 温湿度解析による断熱改修効果の定量的評価Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference伝統的建材の湿気物性に関する研究(その2) ハイグロスコピックモデルの高湿度条件への適用可能性Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference低湿度環境下での乾燥感に関する研究(その12)眼球表面温度の測定と予測モデルの検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference低湿度環境下での乾燥感に関する研究(その11)口腔水分量を用いた量的評価および乾燥感の気道内部位別特性の検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference着衣内空気層の部位別熱抵抗の測定および形状データに基づく推定Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル(その7)強制対流時における着衣内空気層の換気性状解析Oral presentation
- 日本建築学会大会学術講演会, Sep. 2015, Japanese, 日本建築学会, 神奈川, Domestic conference高層ビル全体の換気性状に関する研究 エレベーター扉前後の差圧に影響を及ぼす要因Oral presentation
- 空気調和・衛生工学会大会, Sep. 2015, Japanese, 空気調和・衛生工学会, 大阪, Domestic conference眼の乾燥感に与える温熱環境の影響に関する研究 眼球表面温度の測定と予測モデルの検討Oral presentation
- 空気調和・衛生工学会大会, Sep. 2015, Japanese, 空気調和・衛生工学会, 大阪, Domestic conferenceサーマルマネキンを用いた温熱環境評価法に関する研究(第2 報)等価温度と温冷感申告の対応関係Oral presentation
- 空気調和・衛生工学会大会, Sep. 2015, Japanese, 空気調和・衛生工学会, 大阪, Domestic conferenceサーマルマネキンを用いた温熱環境評価法に関する研究(第1 報)気温の変動に対するマネキン表面熱流の非定常応答特性の測定Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference非定常温冷感予測に関する研究 (その1)皮膚温の部位差を考慮した全身温冷感予測モデルの検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference冬季における寝室の温湿度環境改善に関する研究 温湿度解析による断熱改修効果の定量的評価Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference伝統的建材の湿気物性に関する研究(その2) ハイグロスコピックモデルの高湿度条件への適用可能性Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究(その12)眼球表面温度の測定と予測モデルの検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究(その11)口腔水分量を用いた量的評価および乾燥感の気道内部位別特性の検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference着衣内空気層の部位別熱抵抗の測定および形状データに基づく推定Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル(その7)強制対流時における着衣内空気層の換気性状解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2015, Japanese, 日本建築学会, 大阪, Domestic conference高層ビル全体の換気性状に関する研究 エレベーター扉前後の差圧に影響を及ぼす要因Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference非定常過程における全身温冷感予測式に関する研究‐多様な非定常過程に対する予測式の適用可能性についての検討‐Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference伝統的建材の熱湿気移動特性に関する研究-土壁を対象とした吸放湿過程に関する検討-Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference長期測定データに基づく皮膚含水率予測モデルの検討Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference着衣内空気層の換気性状に関する数値流体解析 着衣の通気抵抗の影響Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference室内気流条件が着衣内空気層の部位別熱抵抗に与える影響Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference高層ビル全体の換気性状の定量的予測に関する研究 EV扉前後の差圧の実測値と計算値の比較Oral presentation
- 第38回人間-生活環境系シンポジウム, Dec. 2014, Japanese, 人間-生活環境系学会, 長崎, Domestic conference眼の乾燥感に与える温熱環境の影響に関する研究-眼球表面温度予測モデルの検討-Oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第44回熱シンポジウム, Oct. 2014, Japanese, 日本建築学会, 大阪, Domestic conference湿気の人・財産・建築に与える影響Oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第44回熱シンポジウム, Oct. 2014, Japanese, 日本建築学会, 大阪, Domestic conference室内温熱環境下での皮膚含水率の非定常応答に関する研究Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference非定常温冷感予測に関する研究 (その1)皮膚温の部位差を考慮した全身温冷感予測モデルの検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference伝統的建材の湿気物性に関する研究 (その1)土壁と漆喰の湿気伝導率測定Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference低湿度環境下での乾燥感に関する研究 (その9)気道内熱水分移動解析モデルに基づく乾燥感予測の検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference低湿度環境下での乾燥感に関する研究 (その8)温湿度が気道内の乾燥感と熱水分移動に及ぼす影響に関する被験者実験Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference低湿度環境下での乾燥感に関する研究 (その7)温湿度・気流による眼球表面温度・瞬目の変化Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference低湿度環境下での乾燥感に関する研究 (その10)人体周囲の温湿度変化や生活行動が皮膚含水率に与える影響の解析Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル (その6)空調機の吹出し気流が着衣内空気層の換気性状に及ぼす影響Oral presentation
- 日本建築学会大会学術講演会, Sep. 2014, Japanese, 日本建築学会, 神戸, Domestic conference高層ビル全体の換気性状の予測に関する研究 冬季におけるエレベーター扉前後の差圧データの解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference非定常温冷感予測に関する研究 (その1)皮膚温の部位差を考慮した全身温冷感予測モデルの検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference伝統的建材の湿気物性に関する研究 (その1)土壁と漆喰の湿気伝導率測定Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その9)気道内熱水分移動解析モデルに基づく乾燥感予測の検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その8)温湿度が気道内の乾燥感と熱水分移動に及ぼす影響に関する被験者実験Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その7)温湿度・気流による眼球表面温度・瞬目の変化Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その10)人体周囲の温湿度変化や生活行動が皮膚含水率に与える影響の解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル (その6)空調機の吹出し気流が着衣内空気層の換気性状に及ぼす影響Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2014, Japanese, 日本建築学会, 大阪, Domestic conference高層ビル全体の換気性状の予測に関する研究 冬季におけるエレベーター扉前後の差圧データの解析Oral presentation
- 第37回人間-生活環境系シンポジウム, Dec. 2013, Japanese, 人間-生活環境系学会, 神戸, Domestic conference着衣内空気層の換気性状に関する数値流体解析 空調機からの吹出し気流の影響Oral presentation
- 第37回人間-生活環境系シンポジウム, Dec. 2013, Japanese, 人間-生活環境系学会, 神戸, Domestic conference室内温熱環境が喉の乾燥感にもたらす影響に関する被験者実験Oral presentation
- 第37回人間-生活環境系シンポジウム, Dec. 2013, Japanese, 人間-生活環境系学会, 神戸, Domestic conference眼の乾燥感に関する研究 瞬き時における眼の表面温度の測定Oral presentation
- 第37回人間-生活環境系シンポジウム, Dec. 2013, Japanese, 人間-生活環境系学会, 神戸, Domestic conferenceデスクワーク中の室内温湿度変化に伴う皮膚含水率の実態調査Oral presentation
- 日本繊維製品消費科学会 第46回快適性を考えるシンポジウム, Oct. 2013, Japanese, 日本繊維製品消費科学会, 京都, Domestic conference着衣における熱・空気・湿気の移動を考慮した体温と温冷感の予測Invited oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第43回熱シンポジウム, Oct. 2013, Japanese, 日本建築学会, 東京, Domestic conferenceオフィスにおける次世代型温熱快適域Oral presentation
- 精密工学会秋季大会シンポジウム, Sep. 2013, Japanese, 精密工学会, 大阪, Domestic conference人体熱モデルを用いた温熱快適性予測の現状と課題Invited oral presentation
- 日本建築学会大会, Aug. 2013, Japanese, 日本建築学会, 北海道, Domestic conference土壁の吸放湿特性に関する研究 平衡含水率曲線の測定と居室の温湿度解析Oral presentation
- 日本建築学会大会, Aug. 2013, Japanese, 日本建築学会, 北海道, Domestic conference低湿度環境下での乾燥感に関する研究(その6)気道内温湿度の実測値に基づくモデルの検討Oral presentation
- 日本建築学会大会, Aug. 2013, Japanese, 日本建築学会, 北海道, Domestic conference高層ビルにおける煙突効果抑制に関する研究 エレベーターシャフトに設ける外部開口を通しての自然換気の効果Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2013, Japanese, 日本建築学会, 大阪, Domestic conference土壁の吸放湿特性に関する研究 平衡含水率曲線の測定と居室の温湿度解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2013, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究(その6)気道内温湿度の実測値に基づくモデルの検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2013, Japanese, 日本建築学会, 大阪, Domestic conference高層ビルにおける煙突効果抑制に関する研究 エレベーターシャフトに設ける外部開口を通しての自然換気の効果Oral presentation
- 日本建築学会環境工学委員会シンポジウム 温熱環境評価における近年の着衣の取り扱いと今後の展開, Feb. 2013, Japanese, 日本建築学会, 東京, Domestic conference着衣における熱・水分移動評価Nominated symposium
- 第36回人間-生活環境系シンポジウム, Dec. 2012, Japanese, 人間-生活環境系学会, 名古屋, Domestic conference気道内熱水分移動モデルに基づく低湿時の室内温熱環境調整法に関する研究Oral presentation
- 第36回人間-生活環境系シンポジウム, Dec. 2012, Japanese, 人間-生活環境系学会, 名古屋, Domestic conference換気回路網計算による着衣内換気の予測Oral presentation
- 第36回人間-生活環境系シンポジウム, Dec. 2012, Japanese, 人間-生活環境系学会, 名古屋, Domestic conferenceオフィスチェアへの着座が人体の非定常温熱生理応答に及ぼす影響Oral presentation
- 第33回日本熱物性シンポジウム, Oct. 2012, Japanese, 日本熱物性学会, 大阪, Domestic conference人体の形状を考慮したCFD解析に基づく着衣内空気層での換気のモデル化Oral presentation
- 第33回日本熱物性シンポジウム, Oct. 2012, Japanese, 日本熱物性学会, 大阪, Domestic conference眼球からの水分蒸発のモデル化 低湿度環境条件下での乾燥感に関する検討Oral presentation
- 第33回日本熱物性シンポジウム, Oct. 2012, Japanese, 日本熱物性学会, 大阪, Domestic conferenceオフィスチェア着座時における人体の非定常温熱生理応答Oral presentation
- 日本建築学会大会, Sep. 2012, Japanese, 日本建築学会, 名古屋, Domestic conference非定常状態における全身温冷感予測に関する研究-皮膚温変化の不均一さに対応した予測式の提案-Oral presentation
- 日本建築学会大会, Sep. 2012, Japanese, 日本建築学会, 名古屋, Domestic conference低湿度環境下での乾燥感に関する研究(その4)眼球および気道からの水分蒸発モデルに関する検討Oral presentation
- 日本建築学会大会, Sep. 2012, Japanese, 日本建築学会, 名古屋, Domestic conference低湿度環境下での乾燥感に関する研究(その5)室内の湿度変化に対する皮膚含水率の非定常応答Oral presentation
- 日本建築学会大会, Sep. 2012, Japanese, 日本建築学会, 名古屋, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル(その5)CFD解析による着衣内空気層の形状と換気性状の関係の検討Oral presentation
- 第21回日本睡眠環境学会学術大会, Aug. 2012, Japanese, 日本睡眠環境学会, 奈良, Domestic conference寝具・寝衣における熱水分移動と人体の温熱生理応答の解析Invited oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2012, Japanese, 日本建築学会, 大阪, Domestic conference非定常状態における全身温冷感予測に関する研究-皮膚温変化の不均一さに対応した予測式の提案-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2012, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究(その4)眼球および気道からの水分蒸発モデルに関する検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2012, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究(その5)室内の湿度変化に対する皮膚含水率の非定常応答Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2012, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル(その5)CFD解析による着衣内空気層の形状と換気性状の関係の検討Oral presentation
- 日本熱物性シンポジウム, Nov. 2011, Japanese, 日本熱物性学会, 横浜市, Domestic conference着衣における熱水分移動を考慮した温熱快適性の解析Oral presentation
- 日本熱物性シンポジウム, Nov. 2011, Japanese, 日本熱物性学会, 横浜市, Domestic conference室内の湿度変化に対する皮膚含水率分布の応答 ラマン分光装置による測定と熱水分同時移動方程式による解析Oral presentation
- 日本生気象学会大会, Nov. 2011, Japanese, 日本生気象学会, 京都市, Domestic conference室内の湿度変化に対する皮膚含水率の応答-低湿時の乾燥感評価のための基礎的検討-Oral presentation
- 第19回発汗学会総会, Sep. 2011, Japanese, 日本発汗学会, 名古屋市, Domestic conference人体熱モデルによる発汗時の数値シミュレーションOral presentation
- 空気調和・衛生工学会大会, Sep. 2011, Japanese, 空気調和・衛生工学会, 名古屋市, Domestic conference乾燥感の評価構造に関する研究 乾燥感の部位別特性と室内温熱環境条件との関係Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference非定常状態における温冷感予測に関する研究 代謝量が変化する過程への2次元温冷感マップの適用可能性Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference低湿度環境下での乾燥感に関する研究 その3 室内の温湿度変化に対する皮膚表層水分の応答Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference低湿度環境下での乾燥感に関する研究 (その2)気道における熱水分移動解析モデルの提案Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference低湿度環境下での乾燥感に関する研究 (その1)皮膚および眼球表面からの蒸発量予測のための基礎的検討Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference人体熱モデルを用いた入浴時の温熱生理反応の解析Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル その4 着衣内空気層の形状データに基づいたCFD解析Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル その3 形状データに基づく着衣内空気層の熱湿気抵抗の推定Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference実住宅に導入されたクールチューブの熱湿気性状の解析 複雑な形状を有する管の簡易モデルに基づく解析と管内空気質評価Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference局所冷暖房に対する睡眠時の温熱生理反応Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京, Domestic conference外気冷房時におけるエレベーターシャフト周辺の温湿度性状に関する検討Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京都, Domestic conference加圧煙制御の遮煙開口部における流量測定に関する研究 -模型実験による外開き扉の常温時における簡易流量測定法の検討-Oral presentation
- 日本建築学会大会, Aug. 2011, Japanese, 日本建築学会, 東京都, Domestic conference加圧煙制御における給気量に関する研究 -空気逃し開口部の設置高さ及び漏気側の煙突効果の影響についての検討-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference非定常状態における温冷感予測に関する研究 代謝量が変化する過程への2次元温冷感マップの適用可能性Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その2)気道における熱水分移動解析モデルの提案Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 (その1)皮膚および眼球表面からの蒸発量予測のための基礎的検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下での乾燥感に関する研究 その3 室内の温湿度変化に対する皮膚表層水分の応答Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルを用いた入浴時の温熱生理反応の解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル その4 着衣内空気層の形状データに基づいたCFD解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル その3 形状データに基づく着衣内空気層の熱湿気抵抗の推定Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference実住宅に導入されたクールチューブの熱湿気性状の解析 複雑な形状を有する管の簡易モデルに基づく解析と管内空気質評価Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference局所冷暖房に対する睡眠時の温熱生理反応Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会, 大阪, Domestic conference外気冷房時におけるエレベーターシャフト周辺の温湿度性状に関する検討Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2011, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference加圧煙制御における給気量に関する研究 -空気逃し開口部の設置高さ及び漏気側の煙突効果の影響についての検討-Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2010, Japanese, 人間-生活環境系学会, 新潟, Domestic conference非定常状態における温冷感予測に関する研究―代謝量が変化する過程への2 次元温冷感マップの適用可能性―Oral presentation
- 第49回日本生気象学会大会, Nov. 2010, Japanese, 日本生気象学会, 東京, Domestic conference非定常状態における温冷感予測に関する研究‐皮膚温を用いた2次元温冷感マップの提案Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2010, Japanese, 人間-生活環境系学会, 新潟, Domestic conference着衣内空気層における換気性状のCFD解析Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2010, Japanese, 人間-生活環境系学会, 新潟, Domestic conference居住者の乾燥意識に配慮した室内温湿度の形成に関する研究-低湿度条件下における皮膚表面での水分蒸発に関する数値計算-Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2010, Japanese, 人間-生活環境系学会, 新潟, Domestic conference居住者の乾燥意識に配慮した室内温湿度の形成に関する研究-湿度変化に対する皮膚表層水分率の応答-Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2010, Japanese, 人間-生活環境系学会, 新潟, Domestic conference換気計算による高層ビル内の湿度・空気質・空調負荷の分布特性の検討Oral presentation
- 第49回日本生気象学会大会, Nov. 2010, Japanese, 日本生気象学会, 東京, Domestic conference乾燥感の評価構造に関する研究 人体熱モデルを用いた解析とアンケート調査Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2010, Japanese, 人間-生活環境系学会, 新潟, Domestic conferenceシャワー浴時の浴室内気流性状のCFD解析Oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第40回熱シンポジウム, Oct. 2010, Japanese, 日本建築学会, 大阪, Domestic conference低湿度環境下における人体表面での水分移動と乾燥感Oral presentation
- 日本建築学会環境工学委員会熱環境運営委員会第40回熱シンポジウム, Oct. 2010, Japanese, 日本建築学会, 大阪, Domestic conference湿害に関する学会規準案の概要Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference非定常状態における温冷感予測に関する研究 皮膚温を用いた2次元温冷感マップの提案Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference冬季における室内湿度および居住者の室内湿度に対する評価の実態Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究-非線形連立方程式の数値解法を用いた隙間量推定法の検討-Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference睡眠時の快適な温熱環境の形成に関する研究 その3 入浴前から起床に至る過程の実験と解析Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル その2 着衣内空気層における換気性状に関するCFD解析Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference人体熱モデルへの適用を目的とした着衣内熱水分移動モデル (その1)着衣内空気層の形状測定と空気層内での熱水分移動のモデル化Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference戸建住宅における地中熱を活かした換気熱損失低減に関する研究 その2 複数住戸の連結したヒート&クールチューブの実測結果Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference居住者の乾燥意識に配慮した室内温湿度の形成に関する研究 その2 皮膚水分率と室内温湿度との関係Oral presentation
- 空気調和・衛生工学会平成21年度学術講演会, Sep. 2010, Japanese, 空気調和・衛生工学会, 山口, Domestic conference乾燥感の評価構造に関する研究 人体熱モデルを用いた解析とアンケート調査Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference加圧煙制御の告示に対応した給気量算定と火災時との対応関係Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conference温・冷風と熱交換を行う潜熱蓄熱体の蓄熱量及び流出空気温度の推定法Oral presentation
- 日本建築学会大会, Sep. 2010, Japanese, 日本建築学会, 富山, Domestic conferenceシャワー浴時における浴室の温熱環境と人体の温熱生理反応の連成解析Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2010, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究-非線形連立方程式の数値解法を用いた隙間量推定法の検討-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2010, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference加圧煙制御の給気量算定における常温時と火災時との対応関係Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2010, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference温・冷風と熱交換を行う潜熱蓄熱体の蓄熱量及び流出空気温度の推定法Oral presentation
- 日本建築学会環境工学委員会シンポジウム 人間と温熱環境における非定常性のとらえ方, Mar. 2010, Japanese, 日本建築学会, 東京, Domestic conference解析モデルに基づく体温調節系および温冷感の非定常特性の予測Nominated symposium
- 第33回人間-生活環境系シンポジウム, Nov. 2009, Japanese, 人間-生活環境系学会, 福岡, Domestic conference発汗条件における着衣周辺の熱水分移動の解析-液相の汗の移動モデル-Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2009, Japanese, 人間-生活環境系学会, 福岡, Domestic conference着衣と皮膚の間に存在する空気層の形状測定と空気層内での熱水分移動のモデル化Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2009, Japanese, 人間-生活環境系学会, 福岡, Domestic conferenceエントランス開放に起因する高層ビルのエレベータシャフトにおける煙突効果抑制に関する研究 その2Oral presentation
- 第33回人間-生活環境系シンポジウム, Nov. 2009, Japanese, 人間-生活環境系学会, 福岡, Domestic conferenceTwo-node modelによる定常状態での皮膚温の再現性 多人数の平均的性状に対する再現性の検討Oral presentation
- 第30回日本熱物性シンポジウム, Oct. 2009, Japanese, 日本熱物性学会, 山形, Domestic conference着衣と皮膚の間に存在する空気層の形状と伝熱性状に関する検討Oral presentation
- 第30回日本熱物性シンポジウム, Oct. 2009, Japanese, 日本熱物性学会, 山形, Domestic conference換気を考慮した着衣の熱水分同時移動モデルに関する研究-発汗を伴う条件下での被験者実験結果に基づくパラメータ推定-Oral presentation
- 空気調和・衛生工学会平成21年度学術講演会, Sep. 2009, Japanese, 空気調和・衛生工学会, 熊本, Domestic conference着衣と皮膚の間に存在する空気層における熱水分移動に関する研究 空気層の形状および熱コンダクタンスの測定Oral presentation
- 空気調和・衛生工学会平成21年度学術講演会, Sep. 2009, Japanese, 空気調和・衛生工学会, 熊本, Domestic conference高層エレベーターシャフトにおける煙突効果に関する研究(その3)換気回路網計算による煙突効果抑止対策の検討Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference非定常状態における温冷感予測式に関する研究 皮膚温を用いた予測式の提案Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference着衣における熱水分同時移動の解析 着衣の水分容量が人体の温熱生理反応に及ぼす影響Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference地下空間火災時における集合竪シャフトを用いた階段加圧煙制御に関する研究Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究-3室5開口の場合-Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference生活空間における温熱生理反応の年内変動に関する研究 人体熱モデルによる解析Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference睡眠時の快適な温熱環境の形成に関する研究 その2 入浴前から起床に至る過程の実験と解析Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference睡眠時の快適な温熱環境の形成に関する研究 その1 冬季の局所空調条件における睡眠実験Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference新旧のTwo-node modelによる安静時の皮膚温の再現性 被験者実験に基づく検討Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference床下暖房時の基礎断熱住宅基礎部からの熱損失の定量的評価Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference戸建住宅における地中熱を活かした換気熱損失低減に関する研究 複数住戸の連結したヒート&クールチューブの提案Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference居住者の乾燥意識に配慮した室内温湿度の形成に関する研究(その1) 暖房時を想定した皮膚水分率の測定定常状態における温冷感予測式に関する研究 皮膚温を用いた予測式の提案Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference加圧煙制御システムの常温における確認方法に関する研究Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conference温風と熱交換を行う顕熱蓄熱体の蓄熱量推定法に関する研究Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conferenceエントランス開放に起因する高層ビルのエレベーターシャフトにおける煙突効果抑制に関する研究Oral presentation
- 日本建築学会大会, Aug. 2009, Japanese, 日本建築学会, 仙台, Domestic conferenceIH調理器上の気流性状に関する研究-周壁による温度及び速度分布への影響の検討-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2009, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究-3室5開口の場合の平面近似を用いた隙間量推定法の検討-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2009, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference床下暖房時の基礎断熱住宅基礎部からの熱損失の定量的評価Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2009, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference加圧煙制御システムの常温における確認方法に関する研究Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2009, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conference温風と熱交換を行う顕熱蓄熱体の蓄熱量推定法に関する研究Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2009, Japanese, 日本建築学会近畿支部, 大阪府, Domestic conferenceIH調理器上の気流性状に関する研究-周壁による温度及び速度分布への影響及び測定方法の検討-Oral presentation
- 第32回人間-生活環境系シンポジウム, Nov. 2008, Japanese, Cheju, Korea, Domestic conference入浴による熱・湿気発生のモデル化 浴槽及びシャワーからの熱・湿気発生Oral presentation
- 第32回人間-生活環境系シンポジウム, Nov. 2008, Japanese, Cheju, Korea, Domestic conferenceエントランス開放に起因する高層ビルのエレベータシャフトにおける煙突効果抑制に関する研究Oral presentation
- 第32回人間-生活環境系シンポジウム, Nov. 2008, Japanese, Cheju, Korea, Domestic conferenceTwo-node modelによる椅座安静時の皮膚温・深部温の再現性 非定常温熱環境での被験者実験に基づく検討Oral presentation
- 2008 Korea-Japan Joint Conference on Wellness @ Living Environment, Nov. 2008, English, Cheju, Korea, International conferenceIndividual difference in transient thermophysiological responses to change in air temperature, A study based on subject experiments for sedentary caseOral presentation
- 日本建築学会大会学術講演会, Sep. 2008, Japanese, 日本建築学会, Hiroshima, Domestic conference体温調節系における個体差の定量化に関する研究(その6) 1986年版Two-node modelに含まれる係数値に関する検討Oral presentation
- 日本建築学会大会学術講演会, Sep. 2008, Japanese, 日本建築学会, Hiroshima, Domestic conference体温調節系における個体差の定量化に関する研究(その5) Passive systemにおける個体の特性が温熱生理反応に与える影響Oral presentation
- 日本建築学会大会学術講演会, Sep. 2008, Japanese, 日本建築学会, Hiroshima, Domestic conference深部温を制御目標とする最適空調制御Oral presentation
- 日本建築学会大会学術講演会, Sep. 2008, Japanese, Hiroshima, Domestic conference戸建住宅における床下空気導入換気方式に関する研究 住宅の実測と数値解析に基づく地盤の熱容量の影響評価Oral presentation
- 日本建築学会大会, Sep. 2008, Japanese, 日本建築学会, 広島, Domestic conference基礎断熱住宅における床下暖房に関する研究 -間欠暖房時における居室の暖房立ち上がり速度改善の検討-Oral presentation
- 日本建築学会大会学術講演会, Sep. 2008, Japanese, Hiroshima, Domestic conferenceカーテンが窓の熱貫流抵抗に及ぼす影響 重力換気を考慮した伝熱解析Oral presentation
- 日本建築学会大会, Sep. 2008, Japanese, 日本建築学会, 広島, Domestic conferenceIH調理器上の気流性状に関する研究 -周壁による温度及び速度分布への影響の検討-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2008, Japanese, 日本建築学会近畿支部, 大阪, Domestic conference基礎断熱住宅における床下暖房に関する研究 -間欠暖房時における居室の暖房立ち上がり速度改善の検討-Oral presentation
- 日本建築学会大会, Aug. 2007, Japanese, 日本建築学会, 福岡, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究 -実住宅を対象とした推定実験-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2007, Japanese, 日本建築学会近畿支部, 大阪, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究 -実住宅における実験および推定値の検討-Oral presentation
- 日本建築学会環境工学委員会シンポジウム 人体熱モデル・熱環境シミュレーションの最前線, Dec. 2006, Japanese, 日本建築学会, 東京, Domestic conference人体熱モデルと体温調節反応における個体差Nominated symposium
- 日本建築学会大会学術講演会, Sep. 2006, Japanese, 日本建築学会, 大阪, Domestic conference入浴時の非定常温熱生理応答 人体熱モデルによる検討Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2006, Japanese, 日本建築学会, 横浜市, Domestic conference地下空間における付室加圧煙制御に関する研究-集合竪シャフト排煙方式での漏煙の検討-Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2006, Japanese, 日本建築学会, 横浜市, Domestic conference地下空間における煙流動と煙制御に関する研究-地下8層の模型実験と一層ゾーンモデルによる数値解析-Oral presentation
- 日本建築学会大会, Sep. 2006, Japanese, 日本建築学会, 神奈川, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究 -CO2のみを用いた模型実験による推定法の妥当性の検討-Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2006, Japanese, 日本建築学会, 横浜市, Domestic conference建築多孔質材料の吸放湿履歴に関する研究-細孔容積分布を用いた履歴の予測法-Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2006, Japanese, 日本建築学会, 横浜市, Domestic conferenceエレベータ利用避難のための煙制御における竪穴給気の給気量決定法Oral presentation
- 日本建築学会近畿支部研究報告集, Jun. 2006, Japanese, 日本建築学会近畿支部, 大阪市, Domestic conference地下空間における煙流動と煙制御に関する研究-地下8層の模型実験と一層ゾーンモデルによる数値解析-Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2006, Japanese, 日本建築学会近畿支部, 大阪, Domestic conference単一ガス濃度測定による多数室間隙間量推定に関する研究 -模型実験による推定法の妥当性の検討-Oral presentation
- 日本建築学会近畿支部研究報告集, Jun. 2006, Japanese, 日本建築学会近畿支部, 大阪市, Domestic conference建築多孔質材料の吸放湿履歴に関する研究-細孔容積分布を用いた履歴の予測法-Oral presentation
- 日本建築学会熱シンポジウム, Nov. 2005, Japanese, 日本建築学会, 滋賀, Domestic conference湿気に由来する建物の問題 -「湿害」をどのように捉えるべきか- 湿害の研究動向Oral presentation
- 日本建築学会大会学術講演会, Sep. 2005, Japanese, 日本建築学会, 大阪, Domestic conference浴槽の断熱効果に関する研究 解析モデルによる熱損失及び室温の評価Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2005, Japanese, 日本建築学会, Domestic conference地下空間における煙流動性状に関する研究-地下8層の模型実験-Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2005, Japanese, 日本建築学会, Domestic conference集合竪ダクト方式の押出排煙ダクト設計法に関する研究Oral presentation
- 日本建築学会大会学術講演会, Sep. 2005, Japanese, 日本建築学会, 大阪, Domestic conference室内の化学物質濃度およびにおいに及ぼす湿度の影響Oral presentation
- 日本建築学会大会学術講演梗概集, Sep. 2005, Japanese, 日本建築学会, Domestic conferenceエレベータ利用避難のための加圧煙制御における給気量決定法に関する研究Oral presentation
- 日本建築学会近畿支部研究発表会, Jun. 2005, Japanese, 日本建築学会近畿支部, 大阪, Domestic conference入浴時の非定常温熱生理応答 人体熱モデルによる検討Oral presentation
- 日本建築学会近畿支部研究報告集 第45号, Jun. 2005, Japanese, 日本建築学会近畿支部, Domestic conference地下空間における煙流動性状に関する研究-地下8層の模型実験-Oral presentation
- 建築学会近畿支部, Jun. 2005, Japanese, 建築学会近畿支部, Domestic conference集合竪ダクト方式の押出排煙ダクト設計法に関する研究Oral presentation
- 日本建築学会近畿支部研究報告集 第45号, Jun. 2005, Japanese, 日本建築学会近畿支部, Domestic conferenceエレベータ利用避難のための加圧煙制御における給気量決定法に関する研究Oral presentation
- 空気調和衛生工学会近畿支部学術研究発表会論文集, 2005, Japanese, 空気調和衛生工学会, 未記入, Domestic conference住宅厨房のIH調理機器に適した配置システム及びキッチン形態に関する研究-温度測定による気流性状の把握および数値計算-Oral presentation
- 日本建築学会大会学術講演会梗概集(環境工学Ⅱ),435-436, Aug. 2004, Japanese, 日本建築学会, 未記入, Domestic conference浴室において発生する水分の移動過程に関する研究(その3)浴室の乾燥過程における換気量と蒸発速度の関係Oral presentation
- 日本建築学会大会学術講演会梗概集(環境工学Ⅱ),503-504, Aug. 2004, Japanese, 日本建築学会, 未記入, Domestic conference非定常状態における温冷感予測式に関する研究 代謝量が大きい場合への適用性の検討Oral presentation
- 日本建築学会大会学術講演会梗概集(環境工学Ⅱ),505-506, Aug. 2004, Japanese, 日本建築学会, 未記入, Domestic conference重ね着した人体各部位における温熱生理量の非定常応答(その1) 着衣における水分蓄積を考慮した着衣間空気温湿度性状の検討Oral presentation
- 日本建築学会大会学術講演会梗概集(環境工学Ⅱ),407-408, Aug. 2004, Japanese, 日本建築学会, 未記入, Domestic conferenceコンクリート壁体の中性化進行予測モデルについての検討Oral presentation
- 室内環境学会Nov. 2023 - Present
- 日本生気象学会Jul. 1999 - Present
- 人間-生活環境系学会May 1999 - Present
- 日本熱物性学会Sep. 1998 - Present
- 空気調和・衛生工学会Jun. 1998 - Present
- 日本建築学会Apr. 1994 - Present
- 日本医療福祉設備協会Oct. 2017 - Mar. 2025
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Scientific Research (B), Kobe University, Apr. 2023 - Mar. 2027Pursue of high-efficiency method for measuring moisture property and validation of analytical model focusing on water vapor adsorption process of building materials
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Scientific Research (C), National Center for Child Health and Development, Apr. 2023 - Mar. 2026Measurement of Insensible Water Loss in Healthy Children
- 日本学術振興会, 科学研究費助成事業 基盤研究(C), 基盤研究(C), 国立保健医療科学院, 01 Apr. 2021 - 31 Mar. 2024高齢者の皮膚不感蒸泄量予測を目指した数値人体非定常応答モデルの開発
- 科学研究費一部基金/基盤研究(B)特設, Apr. 2013 - Mar. 2017, Principal investigatorCompetitive research funding
- 学術研究助成基金助成金/挑戦的萌芽研究, Apr. 2013 - Mar. 2016, Principal investigatorCompetitive research funding
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Challenging Exploratory Research, Kobe University, 2010 - 2012, Principal investigatorTo properly create an indoor environment without sensation of dryness, the mechanism and physical condition of occurrence of dryness were studied. Based on the questionnaire surveys, the existence of the problem and the segments of the body where dryness is sensed were clarified. In addition, a model which predicts moisture evaporation rate from the skin, eye, and throat was developed, and the base of the estimation of dryness of human body according to the environmental conditions such as temperature, humidity, and air velocity was established.Competitive research funding
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Young Scientists (A), Kobe University, 2008 - 2010, Principal investigatorIt is necessary to overcome the complexity of the shape of the air layer in clothing to build up a heat and moisture transfer model in and around clothing adapted for the human thermal model. From this viewpoint, the shape of the air layer in clothing was measured with laser scanner. Based on the data, the heat resistance of the air layer was estimated, and the ventilation characteristics in the air layer were analyzed with computational fluid dynamics. The simultaneous heat and moisture transfer model of clothing was developed taking into account the ventilation in the air layer, and the influence of ventilation was evaluated with using the measured shape data and CFD results. The base of the methodology to analyze the heat and moisture transfer around human body was developed taking into account the complexity of the shape of the air layer in clothing.Competitive research funding
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Scientific Research (C), Osaka Institute of Technology, 2007 - 2008EXAMINATION INTO EVALUATING SYSTEM OF MOISTURE DAMAGES IN BUILDING平成19 年度に最終消費者の「湿害」に関する意識(調査対象地域は福岡県、熊本県、大阪府、滋賀県、兵庫県、関東の諸県、岩手県、北海道である。)について対面調査を行った。各地域ごと、100 から300 の計1000 軒程度の回答を得た。建物や建物を構成する部材、設備を供給する企業での「湿害」の経験収集を行った。商業ビルや工場等大規模建築物については完了し、データベース化を行った。平成20 年度は意識調査回答から湿害の地域特性分析と最終消費者意識の抽出を行うためのデータベース作りをおこなった。居住者が持つ湿害の意識を建物部位・部材で発生する諸現象(16項目)に対する、提案した4意識(建物の耐久性・居住者の健康・使い勝手・見た目に影響する)の回答を評価した。回答された意識を定量化し湿害被害強度と定義した。この湿害被害強度と部位・部材、現象の関係を定量的に評価することで消費者の湿害と判断する現象と部位・部材の関係を整理する作業をおこなっている。関西データについて、先行して整理を行った。
- 日本学術振興会, 科学研究費補助金/若手研究(A), 若手研究(A), 神戸大学, 2005 - 2007, Principal investigator屋外から室内に移動するなど環境条件の変動を念頭に置き、生活空間における体温調節反応に関して、「個体差」を定量的に表現し、その分類を行うことを目的として、非定常過程での被験者実験とそれに対応した人体熱モデルの同定を行った。 昨年度までに、 1. 非定常過程での被験者実験のデータを蓄積し、 2. 1971年版Two-node modelのパラメーター群(皮膚温と深部温のセットポイント値、血流・発汗の制御式の係数値)を、被験者実験一つにつき一組同定するアルゴリズムを開発、同定方法の妥当性を確認し、 3. 被験者実験のデータを基盤として個体の特性を反映したパラメーター群を決定できることを確認し、 4. 決定されたパラメーター群の生理的な位置付けについて検討を行った。 本年度は、以下について検討を行った。 5. 体脂肪率や体重などの情報を用いて、各被験者の代謝量、比熱、熱コンダクタンスを経験式から推定し、人体熱モデル(Two-node model)においてそれらの個体差を考慮した場合の計算結果(非定常過程)への影響が比較的小さいことを示した。 6. 測定値に基づき各被験者の深部温セットポイント値を推定し、それをモデルにおいて考慮することで、ある程度まで計算結果が実験結果に近づくことを示した。 7. 別の人体熱モデル(1986年版Two-node model)を用いた検討を行い、1971年版と同等の結果が得られるかどうかを確認した。基本的には、個体の特性を反映したパラメーター群を同定できるが、外殻率の値が過大である可能性が示された。Competitive research funding
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Scientific Research (B), Kyoto University, 2004 - 2005Indoor climate for comfortable sleep, considering heat and moisture transfer between the room, bedding and human body : Optimal control of an air-conditionerIt is difficult to keep a room comfortable for sleeping compared to waking hours, because the indoor climate cannot be voluntarily controlled according to one's heat sensations, during sleep. If a relationship between thermal comfort for the human body and indoor thermal condition while sleeping is established, thermal environment of the room could be regulated according to the relationship to satisfy thermal comfort during sleep. Since thermal sensation cannot be reported while sleeping, however, relationships between thermal sensation and physiological responses or heat transfer between the human body and ambient environment during sleeping haven't been determined yet. Therefore, we proposed a thermal control system, which feeds back the calculated result of thermal sensation during sleep based on a thermal sensation index while awake and resets the target temperature of an air conditioner. In this study, an air control system providing an indoor thermal environment for comfortable sleep is proposed. This system predicts an index for thermal sensation while sleeping. It can feed back the calculated results to reset the target temperature of an air conditioner. In the present study, sleep experiments were carried out during both summer and winter seasons using a young subject by tentatively assuming a comfortable zone of thermal sensation during sleep under this system. The target temperature was well controlled in conjunction with the predicted value of the thermal sensation index, which converged into the comfortable zone with time. A stable time profile of the predicted values for thermal sensation is closely related to no awakening while sleeping and thus a comfortable sleep. Therefore, the proposed air control system that predicts the thermal sensation index could be effective in creating a comfortable indoor climate for sleep.
- 日本学術振興会, 科学研究費助成事業, 萌芽研究, 2003 - 2004衣服内における熱・湿気・空気の同時移動を考慮した汗の放出過程の定量的検討建築におけるエネルギーの有効利用および快適性向上ために、人体の生理・心理反応の過渡特性を考慮した空調制御が求められている。それに必要な体温変動予測法を構成する観点より、汗の放出過程について衣服内の熱・湿気・空気の移動について検討を行った。 1.衣服内気流性状の把握 被験者を用いた可視化実験を行い、シャツの袖・襟・ボタン周辺等の開口を通しての流出のみならず、布面を貫通する気流が観察された。この気流が汗の放散過程に影響を及ぼす可能性を示した。 2.汗の乾燥過程における衣服内熱・水分・空気移動性状の実測 被験者実験により、汗の乾燥過程における皮膚温、着衣温、衣服内空気層の温湿度、全身での水分損失量について測定を行った。重ね着の状況での汗の蒸発特性を把握した。 3.人体および着衣表面の3次元座標データ作成装置の作成とそれを用いた空気層形状測定 レーザーを用いた表面形状測定システムを用い、皮膚と衣服の間に形成される空気層寸法の測定を試みた。皮膚表面および衣服表面の表面座標から、皮膚と着衣の間に存在する空気層の形状が数値的に求まることを確認した。 4.衣服内換気を考慮した着衣・人体の熱水分同時移動解析 着衣-人体非定常熱水分収支モデルに衣服内の換気を組み込んだプログラムを作成し、衣服内換気が汗の放出過程に及ぼす影響を解析した。 5.皮膚と着衣の間に存在する空気層における自然対流の基礎的検討 単純な人体形状モデルを用いて、自然対流が生じる場合について、室内に立つ人体まわりの気流場の数値解析を行った。衣服下空気層における空気移動量、皮膚-空気層間及び着衣-空気層間の対流熱伝達率を求め、4.のプログラムに入力するべき基礎データを得た。 6.汗の移動経路の解析 重ね着を想定した被験者実験の解析を行い、実験結果を大略再現できることを示した。汗の移動経路を定量的に把握した。
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Scientific Research (A), Kyoto University, 2001 - 2002Prediction of movement, reaction and accumulation of multi-component medium in porous building materialRegarding global environmental, energy and resource problems, longer life and durability of building materials and elements are strongly required in the field of architecture. Since most of the building materials are porous, the prediction and evaluation of movement and accumulation of the moisture and other diffusing substances in porous materials with a suitable precision are very important for an improvement of their durability. The objectives of this research are, to clarify how multi-component, multi-phase media exist, transfer and react in a porous building material, to propose a simplified model, and to develop measuring apparatuses of diffusivity and potential relationships. Experiments on infiltration of acid rain (solution) and diffusion of CO2 gas into concrete sample were carried out in order to investigate the position and degree of neutralization. Based on the results, difference in neutralization rates between gas diffusion and liquid infiltration was clarified. It was also shown that water permeability is significantly different depending on the vertical positions of the test sample. From a viewpoint that the moisture and mass transfer through cracks have a significant influence on neutralization, and it is also affected by the external climates, the influence that the cracks have on the results was examined analytically. A gamma-ray apparatus for man-distractive moisture content measurement was designed and produced. Based on the measured results, several issues related to measurement practice were examined and measurement errors were clarified. A new theoretical approach was proposed which describes the diffusion process of multi-components in a porous material with chemical reactions. Furthermore, a simplified -method for estimating equilibrium relationships of multi-component media was proposed and its validity was examined. In particular, porous structure of and moisture transfer process in a very thin material such as clothing was studied, and an influence that the change in potential relationships caused by salt solution has on the evaporation process.
- 日本学術振興会, 科学研究費助成事業, 基盤研究(C), 京都大学, 2000 - 2001建築材料の熱湿気物性値収集とその評価に関する研究建物の断熱性の評価、結露防止設計、吸放湿材料の性能評価、十分な耐久性を持つ建物の設計などを行う際、建物における熱・湿気の挙動を把握することが必要である。熱・湿気移動の基礎理論についてはほぼ確立されたと言えるが、この理論を用いて実際の現象を予測する際には、熱伝導率、平衡含水率、湿気伝導率などの熱・湿気物性が各材料について整備されていなければならない。ところが、測定の困難さ、測定データの表示方法の多様性などもあって、十分な集積・整理・評価がなされていないのが現状である。これを踏まえて、本研究では、建築材料に関連する熱・湿気物性値を収集し、その評価方法を提案した。具体的には以下の通りである。 1.国内外の文献、試験機関のデータを調査し、物性値を収集した。 2.物性値のばらつきを評価するための標準問題を開発した。水分移動について、蒸気拡散支配領域に限定した標準問題と、液移動をも含む標準問題の両方を作成した。 3.上述の標準問題に関して、フォートラン言語による数値計算プログラムを開発した。 4.数値計算プログラムを用いて、いくつかの建築材料について、実際に物性値の評価を行い、方法論の提案を行った。 5.欧米の大学・研究所で得られた熱・空気・湿気物性値を系統的にまとめたIEA(国際エネルギー機関)Annex24の報告書を翻訳した。その翻訳を日本建築学会から翻訳本として出版する準備を完了した。 (仮題:「建築材料の熱・空気・湿気物性値」、日本建築学会より承認済み、2001年5月脱稿予定。) 6.上述の翻訳本の付録を作成した。付録には、上記2.〜4.の成果を公表すべく、標準問題の提示、数値計算用プログラムのほか、数値計算例、物性データの評価例も掲載されている。
- 日本学術振興会, 科学研究費助成事業, 萌芽的研究, 京都大学, 2000 - 2001密集市街地住宅のエネルギー消費・温熱環境調査と地下蓄熱水槽を利用した地域冷暖房の可能性検討現在、我々は地球温暖化やオゾン層破壊に代表される地球環境問題、化石燃料の枯渇とエネルギー問題、人口・食料問題など、地球レベルでの課題に直面している。従って、これからの都市居住のあり方、街づくりには、未来を展望した環境共生型の都市インフラや都市環境整備が必要とされる。このような状況のなかで求められているのは従来型の都市計画や生活基盤整備ではなく、資源のリサイクルや省エネルギーの観点から、地球環境への負荷軽減を目指す「自立した街の環境計画」と考えられる。 本研究においては、そのような観点に基づき、今後エネルギー需要の伸びが予想される密集市街地住宅を対象に、建物内外の温熱環境を確保しつつ、冷暖房・給湯エネルギー消費量などの観点で「自立する街」を目指した環境共生型の都市インフラや都市環境の整備を目的としている。そのため、本年度は昨年度に引き続き、以下の事項に関する見当を行った。 (1)住戸内の温熱環境調査:大阪市の密集市街地にたつ20戸程度の住宅を対象に、住宅居室の温湿度を測定した。同時に、調査対象地区の屋外温熱環境を調査した。 (2)エネルギー使用量および各住戸の構成に関する調査を行った。住宅の居室内および地域の温熱環境とエネルギー消費との関連を調べ、それに基づき将来のエネルギー使用量を予測した。 (3)住宅内外の温熱環境を予測するモデルを作成し、測定結果の再現を行うとともに、これに基づいて路地空間の温熱環境の改善、冷房用エネルギー消費量を削減する手法を提案した。
- 日本学術振興会, 科学研究費助成事業, 奨励研究(A), 京都大学, 2000 - 2001着衣における水分蓄積が人体の非定常温熱生理に及ぼす影響汗をかいた状態で冷房された室に移行する場合など、体温調節系の非定常過程が空調の設計に対し重要な要素と考えられる状況は多い。そこで、人体に適合した非定常空調制御法を提案することを目的として、発汗とその蒸発過程を想定した被験者実験、およびモデルによる数値解析を行った。検討した項目、および得られた結果は以下の通りである。 1.皮膚-着衣間の熱・水分移動係数の推定 皮膚-着衣間の熱・水分の移動は、発汗量の変動という生理的要素のほか、着衣と皮膚の問に存在する空気層の形状など人間行動の影響を受ける要素や、着衣の熱・水分物性などに関係する。生理的要素については人体熱モデルを用い、皮膚と着衣の間の空気層については皮膚・着衣問の熱・湿気コンダクタンスとしてモデル化し、着衣については熱水分同時移動モデルを適用し、数値解析を行った。被験者実験により得られた皮膚・着衣温の測定結果を用いて、皮膚-着衣間の熱・湿気コンダクタンスを同定することができた。また、発汗とその蒸発を含めた一連の過程での人体・着衣における熱水分移動が、このモデルにより大略予測できることを示した。 2.人体温熱生理モデルの検討 人体の体温調節モデルには調節の目標値が組み込まれている。その温度として通常、唯一の値が与えられているが、複数の被験者のデータを検討すると、熱的中立状態における深部温について、1℃程度の幅でばらつきが見られる。これを深部温の調節目標値におけるばらつきであると仮定し、深部温の調節目標値を変えた場合の解析結果を比較・検討した。深部温の調節目標値における1℃の差が、体温および発汗量の予測値に与える影響は大きい。一方、各被験者実験との対応を検討すると、各被験者の熱的中立時の深部温(測定値)を調節目標値として設定した場合に、モデルの予測精度が高くなることが示された。
- Japan Society for the Promotion of Science, Grants-in-Aid for Scientific Research, Grant-in-Aid for Scientific Research (B), KYOTO UNIVERSITY, 2000 - 2001Development of Aquifer Thermal Storage System for Leveling Electric ConsumptionThe results obtained are summarized as follows. (1) Small scale experiments on thermal storage were carried out based on a similarity rule, which clarified the relationships between hydraulic head and water velocity, flow rate of discharge water temperature, moisture content and stored heat, hygro-thermal properties of the ground and fluxes, and the positions of the well. The results of the analysis based on the heat and mass transfer gave a good agreement with the measured results, thus the analytical model can be used for practical purposes. (2) The temperature and moisture fields including unsaturated region were measured. An unsaturated moisture flow model formulated based on a moving boundary problem could predict the measured results. (3) Based on the measurements of an existing building and ground, the efficiency of the thermal storage was investigated. An examination of the influence of the several factors such as soil characteristics, non-uniform ground strata revealed that the initial temperature distribution has a significant influence on a short term thermal storage, as expected. (4) An optimal method of thermal storage taking into account the control of the building use side was clarified based on a genetic algorithm. (5) Several problems in ground thermal system were identified and the strategies for practical use were proposed.
- 日本学術振興会, 科学研究費助成事業, 奨励研究(A), 京都大学, 1998 - 1999着衣における水分の移動と蓄積を考慮した人体の熱環境に対する非定常応答衣服を身につけた人体の熱環境に対する非定常応答を、発汗がある場合にも予測できるモデルの作成を目的として、以下の検討を行った。 1.汗をかいた状態の被験者を冷房された環境に一定時間滞在させるという実験を行い、深部温、皮膚温、着衣温の変化性状を計測する。 2.皮膚および着衣表面温度分布の経時変化から、皮膚と着衣の接触状況の特性を把握する。 3.連続蒸散・発汗測定装置を活用して、発汗過程における発汗量の変動を計測する。 4.深部温に相当するものとして測定されている腋下温、鼓膜温、直腸温の特性を把握する。 5.汗が蒸発する過程における着衣温変動を十分に再現できるモデルを作成する。 上記の各項目に対応する結論は、それぞれ以下の通りである。 1.部位により、皮膚温に最大で約4℃の差が見られ、汗の蒸発過程における変動パターンも異なる。汗の蓄積量が多い部位ほどが、蒸発による温度低下が長く続く。発汗過程の着衣温に関して、水分の吸着による急激な温度の上昇が見られた。本実験の場合、着衣温の最高値は気温より約2℃高い。 2.赤外線画像より、着衣含水率が比較的高いと思われる部位において、着衣からの熱損失が比較的長時間続く傾向が確認された。また体表面の凹凸により、胸中央などで皮膚と着衣が離れている、逆に腹部で接触しているなどの傾向が示された。 3.発汗過程において皮膚温、深部温、発汗量が単調増加する。 4.高温環境から低温環境へ移動する際の温度変化性状は、腋下、鼓膜、直腸それぞれで異なっていた。 5.着衣の平衡含水率を測定した。また、湿度が階段状に変化する場合の着衣の温度変化を計測した。着衣の温度変化過程について、熱水分同時移動モデルに基づく数値解析を行ったところ、適切な平衡含水率曲線、湿度伝達率を用いれば、実験値を再現できることが確認された。