SEARCH
Search Details
HASEGAWA SusumuResearch Center for Membrane and Film TechnologyResearch Fellow
Researcher basic information
■ Research Areas- Manufacturing technology (mechanical, electrical/electronic, chemical engineering) / Applied biofunctional and bioprocess engineering
- Manufacturing technology (mechanical, electrical/electronic, chemical engineering) / Chemical reaction and process system engineering
- Manufacturing technology (mechanical, electrical/electronic, chemical engineering) / Transfer phenomena and unit operations
Research activity information
■ Award■ Paper
- Elsevier BV, Jan. 2025, Separation and Purification Technology, 352, 128159 - 128159[Refereed]Scientific journal
- Elsevier BV, Nov. 2023, Water Research, 246, 120716 - 120716Scientific journal
- Elsevier BV, Jan. 2023, Journal of Membrane Science, 665, 121122 - 121122[Refereed]Scientific journal
- Jun. 2020, Water Science and Technology, 81(11) (11), 2381 - 2390Scientific journal
- Dec. 2019, Water Science and Technology: Water Supply, 19(8) (8), 2330 - 2337[Refereed]Scientific journal
- Mar. 2019, Water Science and Technology: Water Supply, 19(2) (2), 610 - 617, English[Refereed]Scientific journal
- American Chemical Society, Mar. 2018, Industrial and Engineering Chemistry Research, 57(12) (12), 4430 - 4441, English[Refereed]Scientific journal
- 2017, Water, 9(12) (12), English[Refereed]Scientific journal
- Dec. 2016, WATER, 8(12) (12), English[Refereed]Scientific journal
- Dec. 2016, Water, 8(12) (12), 602, EnglishEffect of membrane material and surface pore size on the fouling properties of the membrane bioreactor (MBR)[Refereed]Scientific journal
- Society of Environmental Conservation Engineering, Aug. 2003, Journal of Environmental Conservation Engineering, 32(8) (8), 654 - 658, Japanese
- Society of Environmental Conservation Engineering, Aug. 1999, Journal of Environmental Conservation Engineering, 28(8) (8), 532 - 534, Japanese
- A novel wastewater treatment process with thermophilic aerobic sludge digestor (TAD) was developed to reduce excess sludge generated from an activated sludge (AS) process. The TAD was operated at 65°C with hydraulic retention time 1day. The SS solubilization and VM removal in the TAD were 35% and 20%, respectively. A 40l-scale conventional AS and new processes with appropriate volume of the TAD were operated under BOD-SS loading of 0.3kg·kg-1·d-1 and MLSS of 2,000mg·l-1 using artificial wastewater over 100d. As a result, the amount of excess sludge was 4.9gSS·d-1 in the conventional AS process. On the other hand, excess sludge in the new process was reduced to nearly zero when 16.2gSS·d-1 was recirculated to the TAD. Effluent BOD was the same level in the both processes, however, effluent S-TOC was 25% higher in the new process than that of the conventional AS process. Furthermore, similar results were obtained from a treatment test with a petrochemical wastewater. The calculated operating cost of the new process was about one third or one half compared to dewatering and landfill processes.Japan Society on Water Environment, Jun. 1998, Journal of Japan Society on Water Environment, 21(6) (6), 360 - 366, Japanese
- PABIO MOVER, a fluidized bed aerobic biofilm treatment process, has many advantages such as high -loading operation, no backwash requirement, flexible reactor design. A demonstration test with a bench scale unit using artificial wastewater confirmed the mechanism of the high-rate treatment: increased oxygen transfer rate by moving carrier elements of special shape, high removal ratio of organic substances with microorganisms, and microbial habitat segragation. Pilot tests using wastewater from brewery and food processing plants achieved removal ratios from 99 to 95% at 4 to 6 kg/m3/d BOD volumetric loading. A commercial unit of the PABIO MOVER is operating successfully at a food processing plant.Society of Environmental Conservation Engineering, 1998, J. Env. cons. eng, 27(5) (5), 362 - 367, Japanese
- A novel wastewater treatment process with thermophilic aerobic sludge digestor (TAD) was developed to reduce excess sludge generated from an activated sludge (AS) process. The TAD was operated at 65°C with hydraulic retention time 1 day. The SS solubilization and VM removal in the TAD were 35% and 20%, respectively. A 40L-scale conventional AS and the new processes with appropriate volume of the TAD were operated under BOD-SS loading of 0.3kg/kg⋅d and MLSS of 2, 000mg/l using artificial wastewater over 100 days. As a result, the amount of excess sludge was 4.9gSS/d in the conventional AS process. On the other hand, excess sludge in the new process was reduced to nearly zero when the amount of excess sludge to be solubilized was three times larger than the expected excess sludge in the conventional AS process. Effluent BOD was the same level in the both processes, however, effluent S-TOC was 25% higher in the new process than that of the conventional AS process. The calculated operating cost of the new process was about one third or one half compared to dewatering and landfill processes.Society of Environmental Conservation Engineering, 1998, Journal of Environmental Conservation Engineering, 27(5) (5), 356 - 361, Japanese
- Society of Environmental Conservation Engineering, 1992, Journal of Environmental Conservation Engineering, 21(8) (8), 509 - 513, Japanese
- Mar. 2019, 環境浄化技術, 18(2) (2), 71 - 75, Japanese気性膜分離法と正浸透膜による省エネ型下水処理システム[Refereed]Introduction scientific journal
- 神鋼環境ソリューション技術開発センター, 2017, 神鋼環境ソリューション技法, 14(1) (1), 2 - 7, Japanese「生物接触ろ過がMF 膜ファウリングに及ぼす影響の評価」[Refereed]Introduction other
- 日本下水道協会, 2016, 下水道研究発表会講演集, 53, 241 - 243, Japanese浸透圧発電を組み合わせた省エネ型膜分離活性汚泥法の開発 (第53回下水道研究発表会講演集)
- 環境技術学会, 20 May 2007, Environmental conservation engineering, 36(5) (5), 322 - 326, JapaneseDecomposition of sludge by thermophilic bacteria
- 紙パルプ技術協会, 01 Aug. 2001, 紙パ技協誌, 55(8) (8), 1129 - 1135, JapaneseDecomposition of Biological Waste Sludge by Thermophilic Bacteria : -S-TE process-(Solubilization by Thermophilic Enzyme)
- 神鋼パンテツク技術開発本部, 2001, 神鋼パンテツク技報, 45(1) (1), 18 - 25, Japanese日本下水道事業団共同研究テーマ 好気性好熱細菌による下水汚泥の減量化--エステプロセスの下水への適用
- 神鋼パンテツク技術開発本部, 2000, 神鋼パンテツク技報, 44(1) (1), 2 - 10, Japaneseエステプロセスの下水汚泥への適用--省エネルギーを目的とした濃縮汚泥処理運転について
- 化学工学会第84.年会, Mar. 2019, Japanese, 化学工学会, 芝浦工業大学, Domestic conference有機溶媒耐性を有する新規PA-TFC膜の開発Poster presentation
- 日本海水学会若手会第10回学生研究発表会, Mar. 2019, Japanese, 日本海水学会若手会, 旧佐世保鎮守府凱旋記念館, Domestic conference電気透析排水から2価陽イオンと2価陰イオンを選択分離する新規ナノ濾過膜の開発Poster presentation
- 日本海水学会若手会第10回学生研究発表会, Mar. 2019, Japanese, 日本海水学会若手会, 佐世保, Domestic conference正浸透膜を用いた下水濃縮に関する検討Oral presentation
- 化学工学会第84.年会, Mar. 2019, Japanese, 化学工学会, 芝浦工業大学, Domestic conference高分子膜を利用した正浸透法における膜ファウリング特性Poster presentation
- 化学工学会第84.年会, Mar. 2019, Japanese, 化学工学会, 芝浦工業大学, Domestic conferenceポリケトン支持膜の構造制御による耐圧性と正浸透膜における透水性への影響Poster presentation
- 化学工学会 中国四国支部;関西支部合同徳島大会, Dec. 2018, Japanese, 徳島大学, Domestic conferenceポリケトン支持膜のアミン修飾による膜構造や耐圧性の影響Oral presentation
- 膜シンポジウム2018, Nov. 2018, Japanese, 神戸, Domestic conference嫌気性膜分離法(AnMBR)における膜ファウリングに関する検討Poster presentation
- 平成30年度全国会議(水道研究発表会), Oct. 2018, Japanese, 日本水道協会, 福岡, Domestic conference本山浄水場における精密ろ過膜モジュールの簡易薬品洗浄に関する検討Oral presentation
- 平成30年度全国会議(水道研究発表会), Oct. 2018, Japanese, 日本水道協会, 福岡, Domestic conference精密ろ過膜モジュールの簡易薬品洗浄に関する検討~ 薬品洗浄廃液組成解析からの洗浄効果の評価 ~Oral presentation
- 第21回日本水環境学会シンポジウム, Sep. 2018, Japanese, 島根県(島根大学), Domestic conference嫌気性膜分離法と正浸透膜による省エネ型下水処理システムの検討Oral presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference有機溶媒耐性を有するポリアミド系複合薄膜の開発Poster presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference電気透析排水中の2価陽イオンと2価陰イオンを分離する新規ナノ濾過膜の開発Poster presentation
- 日本海水学会若手会第9回学生研究発表会, Mar. 2018, Japanese, 東京, Domestic conference電気透析排水から2価陽イオンと2価陰イオンを選択分離する新規ナノ濾過膜の開発Oral presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference中空糸膜を利用した正浸透法および逆浸透法における膜ファウリング特性の比較検討Poster presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference正浸透膜法による食品工程廃水濃縮プロセスに関する研究Poster presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference正浸透膜の選択透過性の向上と糖液濃縮およびバイオエタノール生産に及ぼす効果Poster presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference正浸透膜と嫌気性膜分離法による創エネ型下水処理プロセスに関する検討Poster presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conference三次元蛍光分析を用いた膜ファウリング予測システムの検討Oral presentation
- 化学工学会第83回年会, Mar. 2018, Japanese, 大阪, Domestic conferenceポリケトン膜のアミン修飾による耐圧性向上の要因と正浸透膜への応用Poster presentation
- 地域イノベーション戦略支援プログラム活動報告会, Feb. 2018, Japanese, 神戸, Domestic conference水処理分野における新しい膜処理技術と膜ファウリングについてOral presentation
- 平成29年度全国会議(水道研究発表会), Oct. 2017, Japanese, 香川, Domestic conference膜ろ過前処理設備としての生物接触ろ過装置の性能評価Oral presentation
- 第54回下水道研究発表会, Aug. 2017, Japanese, 東京, Domestic conference嫌気MBRとFO膜処理のハイブリッド化システムにおける膜ファウリングについてOral presentation
- 日本膜学会第39年会, May 2017, Japanese, 東京, Domestic conference上水膜処理における膜ファウリング抑制のための前処理設備の最適化Oral presentation
- 日本膜学会第39年会, May 2017, Japanese, 東京, Domestic conferenceFO膜ファウリング抑制のための前処理膜の検討Poster presentation
- 化学工学会第82年会, Mar. 2017, English, 東京, Domestic conference生物学的前処理による膜ファウリング原因物質の除去に関する検討Poster presentation
- 第19回化学工学会学生発表会(豊中大会), Mar. 2017, Japanese, 大阪, Domestic conference下水処理における正浸透(FO)膜のファウリング特性およびアンモニア阻止性能についての検討Oral presentation
- 平成28年度全国会議(水道研究発表会), Nov. 2016, Japanese, 京都, Domestic conference生物接触ろ過-MF膜ろ過プロセスー原水水質の季節変動が生物接触ろ過に与える影響の評価Oral presentation
- 化学工学会第48回秋季大会, Sep. 2016, Japanese, 徳島, Domestic conference生物接触ろ過過程におけるバイオポリマーの挙動解析Poster presentation
- 化学工学会第48回秋季大会, Sep. 2016, Japanese, 徳島, Domestic conference生物接触ろ過の季節変動とMF膜ファウリングに及ぼす影響Oral presentation
- 化学工学会第48回秋季大会, Sep. 2016, Japanese, 徳島, Domestic conference下水のFO膜濃縮とメタン発酵によるエネルギー回収技術の評価Oral presentation
- 日本膜学会第38 年会, May 2016, Japanese, 東京, Domestic conference膜システムの省エネ・創エネ技術の紹介Oral presentation